## page was renamed from vent/planningFall2021/VertecRacks_InAirCable = Vertex Racks in-air cable length assessment = Cable lengths from Satellite Amplifiers on different racks to the vacuum flanges == Distance from racks to the inner-wall corner(vertex) bottom == ||||||||'''Distance of racks to inner-wall corner bottom for cable'''|| ||'''Rack'''||'''Sat Amps'''||'''Distance description'''||'''Distance (feet)'''|| ||1Y1 (and a small 18U rack)||LO1<
>LO2<
>AS1<
>AS4<
>SR2<
>PR2<
>PR3|| 8'(up-to bridge) <
>+ 2'(side-to bridge) <
>+ 7'(to cross-bdrige) <
>+ 6'(cross to wall) <
>+ 15'(along wall to corner) <
>+ 8'(down-to corner bottom)||46'|| ||1X3||PRM<
>BS<
>ITMX<
>ITMY|| 8'(up-to bridge) <
>+ 4'(side-to bridge) <
> + 28'(along X-arm) <
>+ 12'(cross to wall) <
>+11'(along wall to corner) <
>+ 8'(down-to corner bottom)||71'|| ||1X3||SRM<
>MC1<
>MC3<
>MC2|| 8'(up-to bridge) <
>+ 4'(side-to bridge) <
> + 35'(along X-arm) <
>+ 12'(cross to wall) <
>+11'(along wall to corner) <
>+ 8'(down-to corner bottom)||78'|| == Required cable lengths == ||||||||||'''Required cable lengths'''|| ||'''Optic'''||'''Rack'''||'''Rack to corner bottom'''||'''Distance description <
>from corner bottom <
>to vacuum flange'''||'''Distance (feet)'''||'''To order'''|| ||LO1 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 5'(along ITMX chamber)|| 54' || 70' || ||LO2 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 1'(along BS chamber)|| 56' || 70' || ||AS1 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 3'(cross to ITMY chamber) <
>+ 2'(along ITMY chamber)|| 60' || 70' || ||AS4 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 3'(cross to ITMY chamber) <
>+ 2'(along ITMY chamber)|| 60' || 70' || ||SR2 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 2'(along BS chamber)|| 57' || 70' || ||PR2 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 5'(along ITMX chamber)|| 56' || 70' || ||PR3 || 1Y1 || 46' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 1'(along BS chamber)|| 54' || 70' || ||PRM || 1X3 || 71' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 2'(along BS chamber)|| 82' || 100' || ||BS || 1X3 || 71' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 2'(along BS chamber)|| 82' || 100' || ||ITMX || 1X3 || 71' || 3'(on floor along Y dir) <
>+ 7'(along ITMX chamber)|| 81' || 100' || ||ITMY || 1X3 || 71' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 3'(cross to ITMY chamber) <
>+ 3'(along ITMY chamber)|| 86' || 100' || ||SRM || 1X4 || 78' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 3'(cross to ITMY chamber) <
>+ 1'(along ITMY chamber)|| 91' || 100' || ||MC1 || 1X4 || 78' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 8'(along BS chamber) <
>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC3 || 1X4 || 78' || 3'(on floor along Y dir) <
>+ 6'(cross to BS chamber) <
>+ 8'(along BS chamber) <
>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC2 || 1X4 || - || 8'(up-to bridge) <
>+ 4'(side-to bride) <
>+ 4'(on cross-bridge) <
>+ (8'down-to MC2)|| 24' || 40' || ||ETMX || 1X9 || - || || || 30' || ||ETMY || 1Y4 || - || || || 30' || Cable Order || Cable || Length || Qty || Note || || D2100103 D15-D9 Reducer|| 3ft || 38 || (17 SOSs)x2 + 4 spares || || || || || || || D2100675-01 || 30ft || 4 || ETMX/ETMY || || D2100675-02 || 40ft || 4 || MC2 / Spare || || D2100675-03 || 70ft || 14 || LO1/LO2/AS1/AS4/SR2/PR2/PR3 || || D2100675-04 || 100ft || 10 || PRM/BS/ITMX/ITMY/SRM || || D2100675-04 || 110ft || 6 || MC1/MC3/Spare ||