Size: 3244
Comment:
|
Size: 3372
Comment:
|
| Deletions are marked like this. | Additions are marked like this. |
| Line 15: | Line 15: |
| ||'''Optic'''||'''Rack'''||'''Rack to corner bottom'''||'''Distance description <<BR>>from corner bottom <<BR>>to vacuum flange'''||'''Distance (feet)'''|| ||LO1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 54' || ||LO2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 56' || ||AS1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || ||AS4 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || ||SR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 57' || ||PR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 56' || ||PR3 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 54' || ||PRM || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || ||BS || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || ||ITMX || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 7'(along ITMX chamber)|| 81' || ||ITMY || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 3'(along ITMY chamber)|| 86' || ||SRM || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 1'(along ITMY chamber)|| 91' || ||MC1 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || ||MC3 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || ||MC2 || 1X4 || - || 8'(up-to bridge) <<BR>>+ 4'(side-to bride) <<BR>>+ 4'(on cross-bridge) <<BR>>+ (8'down-to MC2)|| 24' || |
||'''Optic'''||'''Rack'''||'''Rack to corner bottom'''||'''Distance description <<BR>>from corner bottom <<BR>>to vacuum flange'''||'''Distance (feet)'''||'''To order'''|| ||LO1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 54' || 70' || ||LO2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 56' || 70' || ||AS1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || 70' || ||AS4 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || 70' || ||SR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 57' || 70' || ||PR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 56' || 70' || ||PR3 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 54' || 70' || ||PRM || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || 100' || ||BS || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || 100' || ||ITMX || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 7'(along ITMX chamber)|| 81' || 100' || ||ITMY || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 3'(along ITMY chamber)|| 86' || 100' || ||SRM || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 1'(along ITMY chamber)|| 91' || 100' || ||MC1 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC3 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC2 || 1X4 || - || 8'(up-to bridge) <<BR>>+ 4'(side-to bride) <<BR>>+ 4'(on cross-bridge) <<BR>>+ (8'down-to MC2)|| 24' || 40' || |
Vertex Racks in-air cable length assessment
Cable lengths from Satellite Amplifiers on different racks to the vacuum flanges
Distance from racks to the inner-wall corner(vertex) bottom
Distance of racks to inner-wall corner bottom for cable |
|||
Rack |
Sat Amps |
Distance description |
Distance (feet) |
1Y1 (and a small 18U rack) |
LO1 |
8'(up-to bridge) |
46' |
1X3 |
PRM |
8'(up-to bridge) |
71' |
1X3 |
SRM |
8'(up-to bridge) |
78' |
Required cable lengths
Required cable lengths |
|||||
Optic |
Rack |
Rack to corner bottom |
Distance description |
Distance (feet) |
To order |
LO1 |
1Y1 |
46' |
3'(on floor along Y dir) |
54' |
70' |
LO2 |
1Y1 |
46' |
3'(on floor along Y dir) |
56' |
70' |
AS1 |
1Y1 |
46' |
3'(on floor along Y dir) |
60' |
70' |
AS4 |
1Y1 |
46' |
3'(on floor along Y dir) |
60' |
70' |
SR2 |
1Y1 |
46' |
3'(on floor along Y dir) |
57' |
70' |
PR2 |
1Y1 |
46' |
3'(on floor along Y dir) |
56' |
70' |
PR3 |
1Y1 |
46' |
3'(on floor along Y dir) |
54' |
70' |
PRM |
1X3 |
71' |
3'(on floor along Y dir) |
82' |
100' |
BS |
1X3 |
71' |
3'(on floor along Y dir) |
82' |
100' |
ITMX |
1X3 |
71' |
3'(on floor along Y dir) |
81' |
100' |
ITMY |
1X3 |
71' |
3'(on floor along Y dir) |
86' |
100' |
SRM |
1X4 |
78' |
3'(on floor along Y dir) |
91' |
100' |
MC1 |
1X4 |
78' |
3'(on floor along Y dir) |
98' |
110' |
MC3 |
1X4 |
78' |
3'(on floor along Y dir) |
98' |
110' |
MC2 |
1X4 |
- |
8'(up-to bridge) |
24' |