Size: 1077
Comment:
|
Size: 3881
Comment:
|
| Deletions are marked like this. | Additions are marked like this. |
| Line 9: | Line 9: |
| ||1Y3 (and a small 18U rack)||LO1<<BR>>LO2<<BR>>AS1<<BR>>AS4<<BR>>SR2<<BR>>PR2<<BR>>PR3|| 8'(up-to bridge) <<BR>>+ 2'(side-to bridge) <<BR>>+ 7'(to cross-bdrige) <<BR>>+ 6'(cross to wall) <<BR>>+ 15'(along wall to corner) <<BR>>+ 8'(down-to corner bottom)||46'|| | ||1Y1 (and a small 18U rack)||LO1<<BR>>LO2<<BR>>AS1<<BR>>AS4<<BR>>SR2<<BR>>PR2<<BR>>PR3|| 8'(up-to bridge) <<BR>>+ 2'(side-to bridge) <<BR>>+ 7'(to cross-bdrige) <<BR>>+ 6'(cross to wall) <<BR>>+ 15'(along wall to corner) <<BR>>+ 8'(down-to corner bottom)||46'|| |
| Line 12: | Line 12: |
== Required cable lengths == ||||||||||<tablestyle="width: 80%">'''Required cable lengths'''|| ||'''Optic'''||'''Rack'''||'''Rack to corner bottom'''||'''Distance description <<BR>>from corner bottom <<BR>>to vacuum flange'''||'''Distance (feet)'''||'''To order'''|| ||LO1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 54' || 70' || ||LO2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 56' || 70' || ||AS1 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || 70' || ||AS4 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 2'(along ITMY chamber)|| 60' || 70' || ||SR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 57' || 70' || ||PR2 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 5'(along ITMX chamber)|| 56' || 70' || ||PR3 || 1Y1 || 46' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 1'(along BS chamber)|| 54' || 70' || ||PRM || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || 100' || ||BS || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 2'(along BS chamber)|| 82' || 100' || ||ITMX || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 7'(along ITMX chamber)|| 81' || 100' || ||ITMY || 1X3 || 71' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 3'(along ITMY chamber)|| 86' || 100' || ||SRM || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 3'(cross to ITMY chamber) <<BR>>+ 1'(along ITMY chamber)|| 91' || 100' || ||MC1 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC3 || 1X4 || 78' || 3'(on floor along Y dir) <<BR>>+ 6'(cross to BS chamber) <<BR>>+ 8'(along BS chamber) <<BR>>+ 3'(along MC1/3 chamber)|| 98' || 110' || ||MC2 || 1X4 || - || 8'(up-to bridge) <<BR>>+ 4'(side-to bride) <<BR>>+ 4'(on cross-bridge) <<BR>>+ (8'down-to MC2)|| 24' || 40' || ||ETMX || 1X9 || - || || || 30' || ||ETMY || 1Y4 || - || || || 30' || Cable Order || Cable || Length || Qty || Note || || D2100103 D15-D9 Reducer|| 3ft || 38 || (17 SOSs)x2 + 4 spares || || || || || || || D2100675-01 || 30ft || 4 || ETMX/ETMY || || D2100675-02 || 40ft || 4 || MC2 / Spare || || D2100675-03 || 70ft || 14 || LO1/LO2/AS1/AS4/SR2/PR2/PR3 || || D2100675-04 || 100ft || 10 || PRM/BS/ITMX/ITMY/SRM || || D2100675-04 || 110ft || 6 || MC1/MC3/Spare || |
Vertex Racks in-air cable length assessment
Cable lengths from Satellite Amplifiers on different racks to the vacuum flanges
Distance from racks to the inner-wall corner(vertex) bottom
Distance of racks to inner-wall corner bottom for cable |
|||
Rack |
Sat Amps |
Distance description |
Distance (feet) |
1Y1 (and a small 18U rack) |
LO1 |
8'(up-to bridge) |
46' |
1X3 |
PRM |
8'(up-to bridge) |
71' |
1X3 |
SRM |
8'(up-to bridge) |
78' |
Required cable lengths
Required cable lengths |
|||||
Optic |
Rack |
Rack to corner bottom |
Distance description |
Distance (feet) |
To order |
LO1 |
1Y1 |
46' |
3'(on floor along Y dir) |
54' |
70' |
LO2 |
1Y1 |
46' |
3'(on floor along Y dir) |
56' |
70' |
AS1 |
1Y1 |
46' |
3'(on floor along Y dir) |
60' |
70' |
AS4 |
1Y1 |
46' |
3'(on floor along Y dir) |
60' |
70' |
SR2 |
1Y1 |
46' |
3'(on floor along Y dir) |
57' |
70' |
PR2 |
1Y1 |
46' |
3'(on floor along Y dir) |
56' |
70' |
PR3 |
1Y1 |
46' |
3'(on floor along Y dir) |
54' |
70' |
PRM |
1X3 |
71' |
3'(on floor along Y dir) |
82' |
100' |
BS |
1X3 |
71' |
3'(on floor along Y dir) |
82' |
100' |
ITMX |
1X3 |
71' |
3'(on floor along Y dir) |
81' |
100' |
ITMY |
1X3 |
71' |
3'(on floor along Y dir) |
86' |
100' |
SRM |
1X4 |
78' |
3'(on floor along Y dir) |
91' |
100' |
MC1 |
1X4 |
78' |
3'(on floor along Y dir) |
98' |
110' |
MC3 |
1X4 |
78' |
3'(on floor along Y dir) |
98' |
110' |
MC2 |
1X4 |
- |
8'(up-to bridge) |
24' |
40' |
ETMX |
1X9 |
- |
|
|
30' |
ETMY |
1Y4 |
- |
|
|
30' |
Cable Order
Cable |
Length |
Qty |
Note |
D2100103 D15-D9 Reducer |
3ft |
38 |
(17 SOSs)x2 + 4 spares |
|
|
|
|
D2100675-01 |
30ft |
4 |
ETMX/ETMY |
D2100675-02 |
40ft |
4 |
MC2 / Spare |
D2100675-03 |
70ft |
14 |
LO1/LO2/AS1/AS4/SR2/PR2/PR3 |
D2100675-04 |
100ft |
10 |
PRM/BS/ITMX/ITMY/SRM |
D2100675-04 |
110ft |
6 |
MC1/MC3/Spare |