This is the Phantasmical To Do list for the 40m lab: ( severely shortened Jan. 7, 2007 RA)

--In-lock alignment (This is a big one)

--Transfer function characterization

--Ground loop

Power supplies, racks, optical tables, chambers, LSC PDs, cables etc. ** <b>Get rid of all these long cables to the control room !!</b>

Main commissioning tasks (all **) - Noise budget

_ Controls: - Replace c1losepics/c1iscepics temporary cpu with permanent one

- c1susvme2 sometimes loses time synch.

- Replace framebuilder RAID array with fiber link to QFS system.

- LSC front end cpu starts to creep up towards 61 usec.

- QPD Whitening boards: whitening filters aren't switching.

- Protect the front end code against NaNs from ezcademod

- vacuum breakdown trigger failed to act at 3.7 mTorr on IOO pzts _OMC pzts have to be protected also -V1 valve interlock still does not exits! - Vacuum EPICS screen: TP on/off logic; TP readout;

- Front end code slows down considerably when AWG is running?

- LSC rack power is inadequate. Redo the system, add Sorensens?

- Coupling between LSC IQDemod boards and whitening boards:

- Convert all RFPD DC signals to their LSC PD Interface version,

- The new fiber timing system from Sander seems to be working ok.

- Still have big 60 Hz problems.

- Fast DAQ signals from 1Y2.

- Linux framebuilder?

- Are all controls drawings (PDFs) up-to-date on Ben & Jay's web sites?

_ PSL: - Work on the PSLwatch script to handle all the PSL servo state logic.

- Modify ISS to make the DAQ signals fit in the ADC (110B has a +/- 2V range)

_ MC, MZ:

- How about that RF multiplier circuit?

_ SUS, LSC, ASC:

- OSEM sensor glitches: still have them?

- OSEM problems diagnosed by checkosem script.

- Can't put excitations into SIDE OSEM channels.

_ Computers:

- We can't print to hp2550 from any of the operator consoles except linux3.

- Review the stuff in ALH to see if

_ DC readout (all **):

Other:

- beamline as-built documentation. Update ACad drawings.

- cranes - overheating, failures.

- gutters on building.

- replace leaky valve on roughing pump.

- give CaJAGWR attachment:Kirk_CaJAGWR_281106.ppt .

kirk