Differences between revisions 7 and 8
Revision 7 as of 2010-04-16 19:08:11
Size: 1296
Comment:
Revision 8 as of 2012-01-03 23:02:43
Size: 1304
Editor: localhost
Comment: converted to 1.6 markup
Deletions are marked like this. Additions are marked like this.
Line 15: Line 15:
Two useful documents by Seiji are attachment:T960040-00.pdf and attachment:T960158-00.pdf Two useful documents by Seiji are [[attachment:T960040-00.pdf]] and [[attachment:T960158-00.pdf]]

Currently:

RCG models

YEP

yep.mdl model is the Y End Test Mass model.

It calculates the force due to the coil inputs and the geometry of the moving suspension point relative to the test mass. It applies these forces to get the resulting position of the test mass, which is used to provide outputs for the OSEM sensors. The transfer functions and coupling constants need to be set through the MEDM matrices and Foton filter banks.


yep_pitch_pos

This is a simple simulation of just the pos and pitch degrees of freedom, driven just by the x direction suspension point motion.


Useful pieces of information:

Two useful documents by Seiji are T960040-00.pdf and T960158-00.pdf

The calibration for meters per counts can be found in: /cvs/cds/caltech/apps/mDV/extra/C1/calibratedDARMnoise/cal_sub/getDARMcal.m meters per count at 941.54 Hz is:

cal.mcnt * cal.lambda / 2 / pi / cal.Cpp = 1.06e-6 * 1.064e-6 / 2 / 3.14 / 186 =9.65e-16 meters/count

where cal.Cpp is the MICH free swinging peak-to-peak counts

cal.mcnt is the PD1_Q/itmx_LSC_EXC at the calibration frequency (effectively power per excitation count)

cal.lambda is the frequency of the light (1064 nm)

Notes_for_the_RCG_40m_simulated_plant (last edited 2012-01-03 23:02:43 by localhost)