Line 1: Line 1:
The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. = Mode Cleaner =
Line 3: Line 3:
The input mode cleaner length is ~12 m (24 m round trip), the Finesse is ~1300.  . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.
Line 9: Line 11:
=== WFS === == Beam centering ==
 . http://nodus.ligo.caltech.edu:8080/40m/2863
Line 11: Line 14:
To adjust the WFS offsets, watch the C1IOO_WFS_HEADS screen and run the script /cvs/cds/caltech/scripts/MC/WFS/McWFS_dc_offsets to ezcaservo the readbacks to zero.  . http://nodus.ligo.caltech.edu:8080/40m/2864

 . http://nodus.ligo.caltech.edu:8080/40m/2867

 . http://nodus.ligo.caltech.edu:8080/40m/2870

== WFS ==
 . [[MC WFS]]
Line 14: Line 24:
Line 17: Line 26:

OUTPUT MODE CLEANER
The Output Mode Cleaner is mounted into a monolithic copper block cavity, with three fixed mirrors and one PZT length-controlled mirror.

= Documents =

 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-D050379-C], "OMC4 Assembly"
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-D050366-B], "OMC Bezel"
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-D050369-C], "OMC Body"
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-D050370-B], "OMC Cover"
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-E050336-00], "DCN OMC ASSY 40M"

Mode Cleaner

  • The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

Installing the Input Mode Cleaner board

attachment:MC-Schematic.pdf

Beam centering

WFS

Documents