Differences between revisions 3 and 20 (spanning 17 versions)
Revision 3 as of 2007-01-22 04:47:00
Size: 0
Editor: RanaAdhikari
Comment: redundant
Revision 20 as of 2010-05-02 23:15:09
Size: 835
Editor: KojiArai
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

[[Installing the Input Mode Cleaner board]]

attachment:MC-Schematic.pdf

=== Beam centering ===

http://nodus.ligo.caltech.edu:8080/40m/2863
http://nodus.ligo.caltech.edu:8080/40m/2864
http://nodus.ligo.caltech.edu:8080/40m/2865

=== WFS ===

[[MC WFS]]


= Documents =

 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-T020145-00-R], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [http://www.ligo.caltech.edu/docs/T/T020147-00.pdf LIGO-T020147-00-R], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"

The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

Installing the Input Mode Cleaner board

attachment:MC-Schematic.pdf

Beam centering

http://nodus.ligo.caltech.edu:8080/40m/2863 http://nodus.ligo.caltech.edu:8080/40m/2864 http://nodus.ligo.caltech.edu:8080/40m/2865

WFS

MC WFS

Documents

Mode_Cleaner (last edited 2022-08-16 23:41:42 by AnchalguptaATligoDOTorg)