| Line 3: | Line 3: |
| . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz. |
. The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz. |
| Line 10: | Line 8: |
| == Beam centering == | = Beam centering = |
| Line 19: | Line 17: |
| == WFS == | = Alignment Sensing and Control = |
| Line 22: | Line 20: |
| == Analog circuits == | = Analog circuits = |
Mode Cleaner
- The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.
Beam centering
Alignment Sensing and Control
Analog circuits
- [attachment:MC-Schematic.pdf common mode servo circuit board]
Documents
[http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-T020145-00-R], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"