Differences between revisions 26 and 37 (spanning 11 versions)
Revision 26 as of 2010-07-13 00:38:16
Size: 938
Editor: KiwamuIzumi
Comment:
Revision 37 as of 2022-08-16 23:40:38
Size: 1262
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
 . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.  . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.
Line 5: Line 5:
The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz. = Locking =
Lock Settings for IMC. This is required for autolocker to catch lock.
Line 7: Line 8:
[[Installing the Input Mode Cleaner board]] {{attachment:IMC_Lock_Settings.png|IMC Lock settings}}
Line 9: Line 10:
= Mode Cleaner Model =
  . [[MC_model| MC model ]]
 
Line 10: Line 14:

=
= Beam centering ==
= Beam centering =
Line 20: Line 23:
== WFS ==
 . [[MC WFS]]
= Alignment Sensing and Control =
 . [[MC_WFS| MC Wave Front Sensors ]]
Line 23: Line 26:
== Analog circuits == = Analog circuits =
Line 25: Line 28:
 . attachment:MC-Schematic.pdf  . [[attachment:MC-Schematic.pdf|common mode servo circuit board]]
Line 27: Line 30:
= Documents =
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-T020145-00-R], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [http://www.ligo.caltech.edu/docs/T/T020147-00.pdf LIGO-T020147-00-R], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"
= Documents and Links =
 * [[http://www.ligo.caltech.edu/docs/T/T020145-00.pdf|LIGO-T020145-00-R]], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [[http://www.ligo.caltech.edu/docs/T/T020147-00.pdf|LIGO-T020147-00-R]], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"
 * [[RF_ASC]], "Interferometer Wave Front Sensing"

Mode Cleaner

  • The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

Locking

Lock Settings for IMC. This is required for autolocker to catch lock.

IMC Lock settings

Mode Cleaner Model

Beam centering

Alignment Sensing and Control

Analog circuits

Documents and Links

  • LIGO-T020145-00-R, "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"

  • LIGO-T020147-00-R, "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"

  • RF_ASC, "Interferometer Wave Front Sensing"