Differences between revisions 25 and 33 (spanning 8 versions)
Revision 25 as of 2010-07-13 00:36:37
Size: 910
Editor: KiwamuIzumi
Comment:
Revision 33 as of 2012-01-03 23:02:43
Size: 1066
Editor: localhost
Comment: converted to 1.6 markup
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
 . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.  . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.
Line 5: Line 5:
The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.
Line 7: Line 6:
[[Installing the Input Mode Cleaner board]]
Line 9: Line 7:
attachment:MC-Schematic.pdf
Line 11: Line 8:
== Beam centering == = Beam centering =
Line 20: Line 17:
== WFS ==
 . [[MC WFS]]
= Alignment Sensing and Control =
 . [[MC_WFS| MC Wave Front Sensors ]]
Line 23: Line 20:
= Documents =
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-T020145-00-R], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [http://www.ligo.caltech.edu/docs/T/T020147-00.pdf LIGO-T020147-00-R], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"
= Analog circuits =

 . [[attachment:MC-Schematic.pdf|common mode servo circuit board]]

=
Documents and Links =
 * [[http://www.ligo.caltech.edu/docs/T/T020145-00.pdf|LIGO-T020145-00-R]], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [[http://www.ligo.caltech.edu/docs/T/T020147-00.pdf|LIGO-T020147-00-R]], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"
 * [[RF_ASC]], "Interferometer Wave Front Sensing"

Mode Cleaner

  • The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

Beam centering

Alignment Sensing and Control

Analog circuits

Documents and Links

  • LIGO-T020145-00-R, "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"

  • LIGO-T020147-00-R, "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"

  • RF_ASC, "Interferometer Wave Front Sensing"

Mode_Cleaner (last edited 2022-08-16 23:41:42 by AnchalguptaATligoDOTorg)