Differences between revisions 1 and 28 (spanning 27 versions)
Revision 1 as of 2006-09-07 20:19:36
Size: 198
Editor: DanielBusby
Comment:
Revision 28 as of 2010-07-13 00:41:24
Size: 929
Editor: KiwamuIzumi
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
The Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick. = Mode Cleaner =
Line 3: Line 3:
The mode cleaner length is ~12 m (24 m round trip), the Finesse is ~1300.  . The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.




== Beam centering ==
 . http://nodus.ligo.caltech.edu:8080/40m/2863

 . http://nodus.ligo.caltech.edu:8080/40m/2864

 . http://nodus.ligo.caltech.edu:8080/40m/2867

 . http://nodus.ligo.caltech.edu:8080/40m/2870

== WFS ==
 . [[MC WFS]]

== Analog circuits ==

 . [attachment:MC-Schematic.pdf common mode servo circuit board]

= Documents =
 * [http://www.ligo.caltech.edu/docs/T/T020145-00.pdf LIGO-T020145-00-R], "Characterization and commissioning of digital suspensions for the 40m Mode Cleaner"
 * [http://www.ligo.caltech.edu/docs/T/T020147-00.pdf LIGO-T020147-00-R], "Characterizing the length sensing and control system of the mode cleaner in the LIGO 40m lab"

Mode Cleaner

  • The Input Mode Cleaner is a suspended triangular cavity. Each mirror of the triangle is 0.25 kg, 3" in diameter and 1" thick.

The input mode cleaner length is ~13.5 m (27 m round trip), the Finesse is ~1460. Cavity pole is 3.79kHz.

Beam centering

WFS

Analog circuits

  • [attachment:MC-Schematic.pdf common mode servo circuit board]

Documents

Mode_Cleaner (last edited 2022-08-16 23:41:42 by AnchalguptaATligoDOTorg)