 * If you are mad, Steve, don't work on the optics.

Next Generation DC Readout Notes

  • Put the resistors on the PD block, not the nipple.
  • Wider separation for the PDs so the ghost beam can get wedged out.
  • Black glass ring around the PD cans to catch the 1st ghost beam.
  • Black glass dumps all over the place for the leak throughs. Optic mounts should have their own dumps.
  • Don't use any of the Piezo-Jena crap.
  • Don't use copper for the OMC body. All fused-silica, all the time.
  • Don't use a teensy mirror in the OMC. Calculate the needed resonant frequency.
  • Make both curved mirrors on a OMMT movable? And Bigger?
  • always draw ALL the dogs for EVERYTHING
  • CVI mirrors coated for 45P don't get better than ~98% reflectivity
  • change to use a fused silica baseplate with optically contacted mirrors
  • Our current Piezo-Jena mounting system makes leak-through beams un-dumpable. This really
  • really sucks for beams in the dark port. We should put black glass in a "sandwich" style behind
  • the optics.
  • DON'T use Kapton tape in vacuum
  • If you are mad, Steve, don't work on the optics.