Differences between revisions 91 and 95 (spanning 4 versions)
Revision 91 as of 2013-06-05 18:21:21
Size: 3063
Comment:
Revision 95 as of 2013-06-05 18:46:58
Size: 3188
Comment:
Deletions are marked like this. Additions are marked like this.
Line 11: Line 11:
             * Location: ETMY_ISCT at east end of IFO room 104 40m lab
             * Shutter: manual only on NPRO
             * Interlocked: to local emergency shut off switch
             * Location: ETMY_ISCT at east end of IFO room 104, 40m lab
             * Shutter: manual only for 1064 nm on NPRO and local & remote for green
             * Interlocked: to local laser emergency shut off switch (LESS)
Line 31: Line 31:
             * Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
             * Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
             * Interlocked: to global emergency laser shut off swithes at enclosure,
                            entry doors
, EE and SE of room 104
             * Location: PSL Enclosure, at the Vertex of IFO room 104, 40m lab
             * Shutter: manual and remote from MEDM screen & interlocked to vac. 4mT
             * Interlocked:A, to global LESS at enclosure,
                              lab entr
y doors of Vertex, Main, EE and SE of room 104
                           B, to local LESS & option to enable enclosure sliding doors
Line 41: Line 42:
       * Operating: 2A 1W 1064 nm and 1 mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104 40m lab
       * Shutter: manual on laser head for 1064 and local remote for 532nm
       * Interlocked: to local laser emergency shut off switch
       * Operating: 2A 1W 1064 nm and ~1 mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104, 40m lab
       * Shutter: manual on laser head for 1064 and local & remote for green
       * Interlocked: to local LESS
Line 53: Line 54:
 . Interlocked: yes  . Interlocked: to local LESS
  • last update 2013 June 5 SV

LASER INVENTORY and OPERATOR LIST

0, Authorized Laser Operators:

  • Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effler, Keiko Kokeyama, Mike Jenson, Aidan Brooks, Manasadevi Thrugnanasambandam, Eric Quintero, Annalisa Allocca, Yuta Michimura, Riju Chakraborty, Nicolas Smith

1, Lightwave M126-1064-700 sn201, GREEN_LOCKING, Jenne & Manasa

2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji & Steve

  • Operating: 2A 2W 1064 nm, PSL_out 1.4W & 100 microW 532 nm

  • Location: PSL Enclosure, at the Vertex of IFO room 104, 40m lab
  • Shutter: manual and remote from MEDM screen & interlocked to vac. 4mT

  • Interlocked:A, to global LESS at enclosure,

    • lab entry doors of Vertex, Main, EE and SE of room 104
    • B, to local LESS & option to enable enclosure sliding doors

  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Jenne & Manasa

  • Operating: 2A 1W 1064 nm and ~1 mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104, 40m lab
  • Shutter: manual on laser head for 1064 and local & remote for green

  • Interlocked: to local LESS
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: to local LESS
  • SOP

10, JDSU: M126N-1064-700 sn 337,

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)