Differences between revisions 57 and 85 (spanning 28 versions)
Revision 57 as of 2012-01-03 23:02:40
Size: 2841
Editor: localhost
Comment: converted to 1.6 markup
Revision 85 as of 2013-03-04 19:02:01
Size: 3208
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
                                 * last update 2011 July 8 SV
= LASER INVENTORY =
                                                 
                                 * last update 2013 March 4 SV
= LASER INVENTORY and OPERATOR LIST =
0, Authorized Laser Operators:
 Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effler, Keiko Kokeyama, Mike Jenson, Aidan Brooks, Manasadevi Thrugnanasambandam, Eric Quintero, Annalisa Allocca, Yuta Michimura,
 Riju Chakraborty, Nicolas Smith
Line 5: Line 7:
1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh
             * Operating: at 1.8A 400mW of 1064 nm and 4mW of 532nm
                    1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Jenne and Manasa
             * Operating: at 2.1A 790 mW of 1064 nm and 4mW of 532nm
Line 12: Line 16:
2, CrystaLaser 1064nmS of 100mW #81132 at bench MC2: NOT IN USE
Line 14: Line 17:
3, CrystaLaser 1064nm of 180mW # -1274 flq at bench MC2: NOT IN USE 2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1
Line 18: Line 23:
5, Lumix 800-1100nm of 500mW -head only- at cabinet E7 5, Lumix 800-1100nm of 500mW -head only- location: E1
Line 21: Line 26:

Line 32: Line 39:
8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu-Suresh
8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Jenne
Line 49: Line 57:
10, JDSU: M126N-1064-700 sn5519, SPARE, control room 102 10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )
Line 51: Line 59:
11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu 11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Jenne
  • last update 2013 March 4 SV

LASER INVENTORY and OPERATOR LIST

0, Authorized Laser Operators:

  • Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effler, Keiko Kokeyama, Mike Jenson, Aidan Brooks, Manasadevi Thrugnanasambandam, Eric Quintero, Annalisa Allocca, Yuta Michimura, Riju Chakraborty, Nicolas Smith

1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Jenne and Manasa

2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,

  • Operating: 2A 2W 1064 nm, PSL_out 1.4W
  • Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
  • Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
  • Interlocked: to global emergency laser shut off swithes at enclosure,
    • entry doors, EE and SE of room 104
  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Jenne

  • Operating: 2A 1W 1064 nm and 4mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104 40m lab
  • Shutter: manual on laser head for 1064 and local remote for 532nm
  • Interlocked: to local laser emergency shut off switch
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: yes
  • SOP

10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )

11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Jenne

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)