Differences between revisions 4 and 76 (spanning 72 versions)
Revision 4 as of 2009-02-06 22:18:30
Size: 866
Editor: SteveVass
Comment:
Revision 76 as of 2012-03-01 00:46:01
Size: 3095
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
----
 /!\ '''Edit conflict - other version:'''
                                 * last update 2012 March 1 SV
= LASER INVENTORY and OPERATOR LIST =
0, Authorized Laser Operators:
 Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effle, Keiko Kokeyama, Mike Jensen, Aidan Brooks
Line 4: Line 6:
----
----
 /!\ '''Edit conflict - your version:'''
                  
Line 8: Line 8:
----
 [ attachment:opencov ]
1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh
             * Operating: at 2.1A 790 mW of 1064 nm and 4mW of 532nm
             * Location: ETMY_ISCT at east end of IFO room 104 40m lab
             * Shutter: manual only on NPRO
             * Interlocked: to local emergency shut off switch
             * SOP: [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
             * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
Line 11: Line 16:
attachment:opencov2 2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)
Line 13: Line 18:
attachment:PA%23102 3, CrystaLaser 1064nm of 180mW # -1274, location: E1
Line 15: Line 20:
Lightwave MOPA, PA#102 at 60,755hrs, output: ~5W, NPRO#206
40M Laser Inventory at Feb 05, 2009
4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
Line 19: Line 27:
1, Lightwave PA#102 @ 77,910 hrs 1064nm of 2.8W @ 27.65A
                   NPRO#206 @ 2.4A at PSL enclosure

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,
             * Operating: 2A 2W 1064 nm, PSL_out 1.4W
             * Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
             * Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
             * Interlocked: to global emergency laser shut off swithes at enclosure,
                            entry doors, EE and SE of room 104
             * SOP: . [[attachment:Approved 40mLab 2W NPRO.pdf|SOP]]

             * MANUAL: [[attachment:mephisto2wA.pdf]] [[attachment:mephisto2wB.pdf]]
Line 23: Line 39:
2, Lightwave 1064nm of 700mW #415 at AP table 8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu
       * Operating: 2A 1W 1064 nm and 4mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104 40m lab
       * Shutter: manual on laser head for 1064 and local remote for 532nm
       * Interlocked: to local laser emergency shut off switch
       * SOP: . [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
  . http://www.innolight.de/docs/mephisto.html http://www.innolight.de/docs/mephisto_q.html
Line 26: Line 48:
3, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet 9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today
Line 28: Line 50:
 . location: SP-table
Line 29: Line 52:
4, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup  . Interlocked: yes
Line 31: Line 54:
 . [[attachment:Approved Phase_camera_NPRO-SOP-v2.pdf|SOP]]
Line 32: Line 56:
5, RF-PD tester 1064nm of 1.2mW @20mA at SP table


6, Lumix 800-1100nm of 500mW at east arm cabinet


7, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
    plus four spares in east arm cabinet
----
 /!\ '''End of edit conflict'''

----
10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )
                                 
11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu
              * Operating: at 1.8A 360mW of 1064nm
              * Location: AP_ISCT at Vertex
              * Shutter: manual only at NPRO
              * Interlocked: to local emergency shut off switch
              * SOP: .[[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
              * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
  • last update 2012 March 1 SV

LASER INVENTORY and OPERATOR LIST

0, Authorized Laser Operators:

  • Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effle, Keiko Kokeyama, Mike Jensen, Aidan Brooks

1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh

2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,

  • Operating: 2A 2W 1064 nm, PSL_out 1.4W
  • Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
  • Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
  • Interlocked: to global emergency laser shut off swithes at enclosure,
    • entry doors, EE and SE of room 104
  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu

  • Operating: 2A 1W 1064 nm and 4mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104 40m lab
  • Shutter: manual on laser head for 1064 and local remote for 532nm
  • Interlocked: to local laser emergency shut off switch
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: yes
  • SOP

10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )

11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)