Differences between revisions 4 and 58 (spanning 54 versions)
Revision 4 as of 2009-02-06 22:18:30
Size: 866
Editor: SteveVass
Comment:
Revision 58 as of 2012-02-29 19:05:47
Size: 3095
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
----
 /!\ '''Edit conflict - other version:'''
                                 * last update 2012 March 1 SV
= LASER INVENTORY and OPERATOR LIST =
                                                 
Line 4: Line 5:
----
----
 /!\ '''Edit conflict - your version:'''
1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh
             * Operating: at 2.1A 790 mW of 1064 nm and 4mW of 532nm
             * Location: ETMY_ISCT at east end of IFO room 104 40m lab
             * Shutter: manual only on NPRO
             * Interlocked: to local emergency shut off switch
             * SOP: [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
             * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)
Line 8: Line 14:
----
 [ attachment:opencov ]
3, CrystaLaser 1064nm of 180mW # -1274, location: E1
Line 11: Line 16:
attachment:opencov2 4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table
Line 13: Line 18:
attachment:PA%23102 5, Lumix 800-1100nm of 500mW -head only- location: E1
Line 15: Line 20:
Lightwave MOPA, PA#102 at 60,755hrs, output: ~5W, NPRO#206
40M Laser Inventory at Feb 05, 2009
6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,
             * Operating: 2A 2W 1064 nm, PSL_out 1.4W
             * Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
             * Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
             * Interlocked: to global emergency laser shut off swithes at enclosure,
                            entry doors, EE and SE of room 104
             * SOP: . [[attachment:Approved 40mLab 2W NPRO.pdf|SOP]]

             * MANUAL: [[attachment:mephisto2wA.pdf]] [[attachment:mephisto2wB.pdf]]

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu-Jenne-Jamie
       * Operating: 2A 1W 1064 nm and 4mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104 40m lab
       * Shutter: manual on laser head for 1064 and local remote for 532nm
       * Interlocked: to local laser emergency shut off switch
       * SOP: . [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
  . http://www.innolight.de/docs/mephisto.html http://www.innolight.de/docs/mephisto_q.html
Line 19: Line 41:
1, Lightwave PA#102 @ 77,910 hrs 1064nm of 2.8W @ 27.65A
                   NPRO#206 @ 2.4A at PSL enclosure
9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

 . location: SP-table

 . Interlocked: yes

 . [[attachment:Approved Phase_camera_NPRO-SOP-v2.pdf|SOP]]

10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )
                                 
11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu
              * Operating: at 1.8A 360mW of 1064nm
              * Location: AP_ISCT at Vertex
              * Shutter: manual only at NPRO
              * Interlocked: to local emergency shut off switch
              * SOP: .[[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
              * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
Line 23: Line 60:
2, Lightwave 1064nm of 700mW #415 at AP table =LASER OPERATOR LIST=
Line 25: Line 62:

3, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet


4, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup


5, RF-PD tester 1064nm of 1.2mW @20mA at SP table


6, Lumix 800-1100nm of 500mW at east arm cabinet


7, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
    plus four spares in east arm cabinet
----
 /!\ '''End of edit conflict'''

----
Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Drigger, Suresh Dolovari,
Jamie Rollins, Den Martynov, Zack Korth, Aidan Brooks, Mike Jensen, Valery Frolov,
  • last update 2012 March 1 SV

LASER INVENTORY and OPERATOR LIST

1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh

2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,

  • Operating: 2A 2W 1064 nm, PSL_out 1.4W
  • Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
  • Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
  • Interlocked: to global emergency laser shut off swithes at enclosure,
    • entry doors, EE and SE of room 104
  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu-Jenne-Jamie

  • Operating: 2A 1W 1064 nm and 4mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104 40m lab
  • Shutter: manual on laser head for 1064 and local remote for 532nm
  • Interlocked: to local laser emergency shut off switch
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: yes
  • SOP

10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )

11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu

=LASER OPERATOR LIST=

Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Drigger, Suresh Dolovari, Jamie Rollins, Den Martynov, Zack Korth, Aidan Brooks, Mike Jensen, Valery Frolov,

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)