Line 1: Line 1:
attachment:opencov2                                  * last update 2013 June 5 SV
= LASER INVENTORY and OPERATOR LIST =
0, Authorized Laser Operators:
 Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effler, Keiko Kokeyama, Mike Jenson, Aidan Brooks, Manasadevi Thrugnanasambandam, Eric Quintero, Annalisa Allocca, Yuta Michimura,
 Riju Chakraborty, Nicolas Smith
Line 3: Line 7:
attachment:PA%23102                   
Line 5: Line 9:
Lightwave MOPA, PA#102 at 60,755hrs, output: ~5W, NPRO#206 1, Lightwave M126-1064-700 sn 238, GREEN_LOCKING, Jenne & Manasa
             * Operating: at 1.82 A ~331 mW of 1064 nm and 0.8 mW of 532nm
             * Location: ETMY_ISCT at east end of IFO room 104, 40m lab
             * Shutter: manual only for 1064 nm on NPRO and local & remote for green
             * Interlocked: to local laser emergency shut off (LESO) switch
             * SOP: [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
             * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx

2, CrystaLaser 1064nm of 100mW #81132, location: table next to E2 (East arm cabinet 2)

3, CrystaLaser 1064nm of 180mW # -1274, location: E3

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at table next to 1X3 rack

5, Lumix 800-1100nm of 500mW -head only- location: E3

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,



7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji, Jenne & Steve
             * Operating: 2A 2W 1064 nm, PSL_out 1.3W & 100 microW 532 nm
             * Location: PSL Enclosure, at the Vertex of IFO room 104, 40m lab
             * Shutter: manual and remote from MEDM screen & interlocked to vac. 4mT
             * Interlocked:A, to global LESO at lab entry doors
                              of Main-entrance, Vertex, EE and SE of room 104
                           B, to local LESO & option to enable enclosure sliding doors
             * SOP: . [[attachment:Approved 40mLab 2W NPRO.pdf|SOP]]

             * MANUAL: [[attachment:mephisto2wA.pdf]] [[attachment:mephisto2wB.pdf]]


8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Jenne & Manasa
       * Operating: 2A 1W 1064 nm and ~1 mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104, 40m lab
       * Shutter: manual on laser head for 1064 and local & remote for green
       * Interlocked: to local LESO
       * SOP: . [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
  . http://www.innolight.de/docs/mephisto.html http://www.innolight.de/docs/mephisto_q.html


9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

 . location: SP-table

 . Interlocked: to local LESO

 . [[attachment:Approved Phase_camera_NPRO-SOP-v2.pdf|SOP]]

10, Lightwave: M126N-1064-700 sn 337,
              * operating: new comer from ATF
              * location:south east corner of PSL enclosure
              * shutter: manual at NPRO
              * interlock: to local LESO next to NPRO on optical table
              * SOP: .[[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
              * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx

11, Regret to say that Lightwave NPRO sn 415 died in service at ETMY at age ~15
  • last update 2013 June 5 SV

LASER INVENTORY and OPERATOR LIST

0, Authorized Laser Operators:

  • Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effler, Keiko Kokeyama, Mike Jenson, Aidan Brooks, Manasadevi Thrugnanasambandam, Eric Quintero, Annalisa Allocca, Yuta Michimura, Riju Chakraborty, Nicolas Smith

1, Lightwave M126-1064-700 sn 238, GREEN_LOCKING, Jenne & Manasa

2, CrystaLaser 1064nm of 100mW #81132, location: table next to E2 (East arm cabinet 2)

3, CrystaLaser 1064nm of 180mW # -1274, location: E3

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at table next to 1X3 rack

5, Lumix 800-1100nm of 500mW -head only- location: E3

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji, Jenne & Steve

  • Operating: 2A 2W 1064 nm, PSL_out 1.3W & 100 microW 532 nm

  • Location: PSL Enclosure, at the Vertex of IFO room 104, 40m lab
  • Shutter: manual and remote from MEDM screen & interlocked to vac. 4mT

  • Interlocked:A, to global LESO at lab entry doors

    • of Main-entrance, Vertex, EE and SE of room 104
    • B, to local LESO & option to enable enclosure sliding doors

  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Jenne & Manasa

  • Operating: 2A 1W 1064 nm and ~1 mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104, 40m lab
  • Shutter: manual on laser head for 1064 and local & remote for green

  • Interlocked: to local LESO
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: to local LESO
  • SOP

10, Lightwave: M126N-1064-700 sn 337,

11, Regret to say that Lightwave NPRO sn 415 died in service at ETMY at age ~15