Differences between revisions 17 and 22 (spanning 5 versions)
Revision 17 as of 2010-04-23 17:49:59
Size: 950
Editor: SteveVass
Comment:
Revision 22 as of 2010-09-10 18:06:38
Size: 1071
Editor: SteveVass
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:


Line 5: Line 2:
                         4-23-2010                          10 September 2010
Line 9: Line 6:
1, Lightwave PA#102 @ 88,304 hrs 1064nm of 2.8W @ 27.65A at 4-23-2010
Line 11: Line 7:
             NPRO#206 @ 2.4A at PSL enclosure                                                                                                                         1, Lightwave 1064nm of 700mW #415 at AP table
Line 13: Line 12:
2, Lightwave  1064nm of 700mW  #415 at AP table 2, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet
Line 15: Line 14:
3, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet 3, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup
Line 17: Line 16:
4, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup 4, RF-PD tester 1064nm of 1.2mW @20mA at SP table
Line 19: Line 18:
5, RF-PD tester 1064nm of 1.2mW @20mA at SP table 5, Lumix 800-1100nm of 500mW at east arm cabinet
Line 21: Line 20:
6, Lumix 800-1100nm of 500mW at east arm cabinet 6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
Line 23: Line 22:
7, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

8, Innolight-
Mephisto 2000, sn 1907, 1064 nm of 2W,from LLO at 2-1-2010,

location:  SP-table 4-20-2010, 25C 2A 2W #2822

9, Innolight- Mephisto: model 1000, sn 1634, 1064 nm of 1W at 2A,
7, Innolight- Mephisto: M2000NE, sn 1907, 1064 nm of 2W,from LLO at 2-1-2010,
  location: PSL enclosure, 25C 2A 2W #2822
               Interlocked to IFO main laser emergency shut off switch
8, Innolight- Mephisto: model 1000, sn 1634, 1064 nm of 1W at 2A,
Line 31: Line 27:
                Interlocked to local laser emergency shut off switch
  • LASER INVENTORY
    • 10 September 2010

1, Lightwave 1064nm of 700mW #415 at AP table

2, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet

3, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup

4, RF-PD tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW at east arm cabinet

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, 1064 nm of 2W,from LLO at 2-1-2010,

  • location: PSL enclosure, 25C 2A 2W #2822
  • Interlocked to IFO main laser emergency shut off switch

8, Innolight- Mephisto: model 1000, sn 1634, 1064 nm of 1W at 2A,

  • location:SE-table 4-21-2010
  • Interlocked to local laser emergency shut off switch

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)