Differences between revisions 15 and 71 (spanning 56 versions)
Revision 15 as of 2010-04-23 17:24:30
Size: 1105
Editor: SteveVass
Comment:
Revision 71 as of 2012-03-01 00:40:47
Size: 3099
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
[attachment:opencov ]                                  * last update 2012 March 1 SV
= LASER INVENTORY and OPERATOR LIST =
0, Authorized Laser Operators:
 Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effle, Keiko Kokeyama, Mike Jensen, Aidan Brooks
                  
Line 3: Line 7:
[attachment:opencov 40M LASER INVENTORY ] 1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh
             * Operating: at 2.1A 790 mW of 1064 nm and 4mW of 532nm
             * Location: ETMY_ISCT at east end of IFO room 104 40m lab
             * Shutter: manual only on NPRO
             * Interlocked: to local emergency shut off switch
             * SOP: [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
             * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)
Line 5: Line 16:
[attachment:opencov ] 3, CrystaLaser 1064nm of 180mW # -1274, location: E1
Line 7: Line 18:
[attachment:opencov attachment:opencov] 4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table
Line 9: Line 20:
attachment:opencov2 5, Lumix 800-1100nm of 500mW -head only- location: E1
Line 11: Line 22:
attachment:PA%23102 6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
Line 13: Line 24:
Lightwave MOPA, PA#102 at 60,755hrs, output: ~5W, NPRO#206 40M Laser Inventory at Feb 05, 2009 7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,
             * Operating: 2A 2W 1064 nm, PSL_out 1.4W
             * Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
             * Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
             * Interlocked: to global emergency laser shut off swithes at enclosure,
                            entry doors, EE and SE of room 104
             * SOP: . [[attachment:Approved 40mLab 2W NPRO.pdf|SOP]]
Line 15: Line 32:
1, Lightwave PA#102 @ 77,910 hrs 1064nm of 2.8W @ 27.65A              * MANUAL: [[attachment:mephisto2wA.pdf]] [[attachment:mephisto2wB.pdf]]
Line 17: Line 34:
 . NPRO#206 @ 2.4A at PSL enclosure
Line 19: Line 35:
2, Lightwave 1064nm of 700mW #415 at AP table 8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu-Jenne-Jamie
       * Operating: 2A 1W 1064 nm and 4mW 532 nm
       * Location: ETMX_ISCT at south end of IFO room 104 40m lab
       * Shutter: manual on laser head for 1064 and local remote for 532nm
       * Interlocked: to local laser emergency shut off switch
       * SOP: . [[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
  . http://www.innolight.de/docs/mephisto.html http://www.innolight.de/docs/mephisto_q.html
Line 21: Line 43:
3, CrystaLaser 1064nmS of 100mW #81132 at east arm cabinet
Line 23: Line 44:
4, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup 9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today
Line 25: Line 46:
5, RF-PD tester 1064nm of 1.2mW @20mA at SP table  . location: SP-table
Line 27: Line 48:
6, Lumix 800-1100nm of 500mW at east arm cabinet  . Interlocked: yes
Line 29: Line 50:
7, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,  . [[attachment:Approved Phase_camera_NPRO-SOP-v2.pdf|SOP]]
Line 31: Line 52:
 . plus four spares in east arm cabinet

8, Innolight- Mephisto 2000, sn 1907, 1064 nm of 2W,from LLO at 2-1-2010,

 . location: SP-table 4-20-2010, 25C 2A 2W #2822

9, Innolight- Mephisto: model 1000, sn 1634, 1064 nm of 1W at 2A, location:SE 4-21-2010

 . http://www.innolight.de/docs/mephisto.html http://www.innolight.de/docs/mephisto_q.html
10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )
                                 
11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu
              * Operating: at 1.8A 360mW of 1064nm
              * Location: AP_ISCT at Vertex
              * Shutter: manual only at NPRO
              * Interlocked: to local emergency shut off switch
              * SOP: .[[attachment:Approved 1WNPRO-SOP-v4.pdf|SOP]]
              * http://www.jdsu.com/en-us/Lasers/Products/A-Z-Product-List/Pages/laser-solid-state-cw-1064-1319-npro-125-126.aspx
  • last update 2012 March 1 SV

LASER INVENTORY and OPERATOR LIST

0, Authorized Laser Operators:

  • Koji Arai, Rana Adhikari, Steve Vass, Kiwamu Izumi, Jenne Driggers, Jamie Rollins, Suresh Doravari, Valery Frolov, Den Martynov, Zack Korth, Anamaria Effle, Keiko Kokeyama, Mike Jensen, Aidan Brooks

1, Lightwave M126-1064-700 sn415, GREEN_LOCKING, Kiwamu and Suresh

2, CrystaLaser 1064nmS of 100mW #81132, location: E1 (East arm cabinet 1)

3, CrystaLaser 1064nm of 180mW # -1274, location: E1

4, RF-PD Jenne's-tester 1064nm of 1.2mW @20mA at SP table

5, Lumix 800-1100nm of 500mW -head only- location: E1

6, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,

7, Innolight- Mephisto: M2000NE, sn 1907, MAIN_40m_IFO_LASER, Koji- Steve,

  • Operating: 2A 2W 1064 nm, PSL_out 1.4W
  • Location: PSL Enclosure, at the Vertex of IFO room 104 40m lab
  • Shutter: manual and remote from MEDM screen and interlocked to vac. 4mT
  • Interlocked: to global emergency laser shut off swithes at enclosure,
    • entry doors, EE and SE of room 104
  • SOP: . SOP

  • MANUAL: mephisto2wA.pdf mephisto2wB.pdf

8, Innolight- Mephisto: model 1000, sn 1634, GREEN_LOCKING, Kiwamu-Jenne-Jamie

  • Operating: 2A 1W 1064 nm and 4mW 532 nm
  • Location: ETMX_ISCT at south end of IFO room 104 40m lab
  • Shutter: manual on laser head for 1064 and local remote for 532nm
  • Interlocked: to local laser emergency shut off switch
  • SOP: . SOP

9, Innolight- Mephisto:800NE, 837mW 2.1A was at May 2001, old-low quality today

  • location: SP-table
  • Interlocked: yes
  • SOP

10, JDSU: M126N-1064-700 sn5519, SPARE, location: S15 (south arm, "clean room" cabinet 15 )

11, Ligthwave M126-1064-700 sn201, ASBL cavity measurement, Kiwamu

Laser_Inventory (last edited 2018-12-13 19:30:08 by GautamvenugopalanATligoDOTorg)