## page was renamed from Upgrade 09/IFO Modeling/Curvature Mismatch = Effect of the end mirror curvature error to the contrast of ¥¥a Fabry-Perot based Michelson interferometer = We found that one of the ETMs of the 40m interferometer could be delivered with a curvature error of 5¥% from the nominal radius. The effect of this curvature error to the contrast of a FPMI was investigated by analytical calculation and simulations with FINESSE. [[attachment:curvature_mismatch.pdf|Here]] is the document. For the parameter similar to the 40m interferometer with nominal end mirror curvature of 57 m, the contrast defect of the FPMI is given by: . dC = 3.61 x 10^-4^ dR^2^ + O^3^(dR) and this is dominated by the higher-order modes. The result was confirmed with simulations on FINESSE. {{attachment:curvature_mismatch_plot.png}} Relationship between the curvature error and the contrast defect. Red dots show the simulated results. The blue line is the curve for the analytical calculation.