Differences between revisions 2 and 12 (spanning 10 versions)
Revision 2 as of 2010-11-23 08:28:40
Size: 291
Comment:
Revision 12 as of 2011-01-19 11:35:28
Size: 1390
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:

The data for the following measurements is located at [https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/RFphotodiodes/POX/ /svn/trunk/docs/upgrade08/RFsystem/RFphotodiodes/POX/]
Line 7: Line 9:
The resonance peaks at 11, 22, and 55 MHz were measured in detail and fit to a resonance curve (see below) with the following results

|| Resonance Frequency || Transimpedance at Resonance || Q ||
|| (11.14 +- 0.01) MHz || (2.206 +- 0.001) kOhms || 14.58 +- 0.01 ||
|| (22.68 +- 0.01) MHz || (9.681 +- 0.003) Ohms || 27.66 +- 0.01 ||
|| (55.29 +- 0.01) MHz || (475 +- 2) mOhms || 31.81 +- 0.05 ||

=== Fits To Resonance ===

==== 11 MHz Resonance ====

attachment:res1.png

f,,0,, = (11.14 +- 0.01) MHz
Gamma = (764 +- 1) kHz
R,,0,, = (8.38 +- 0.01) x 10^8^ Hz Ohms
C = (11.14 +- 0.05) Ohms
chi^2/ndf = 95.4

==== 22 MHz Resonance ====

attachment:res2.png

==== 55 MHz Resonance ====

attachment:res3.png
Line 11: Line 40:
The measured dark noise was (21 +- 2) nV/rtHz.
The noise data was fit to with the following results:
V,,d,, = (21 +- 2) nV/rtHz
Z,,RF,, = (77 +- 3) kOhms
chi^2^ / ndf = 0.006
The noise data was fit to attachment:fitfunc.png with the following results:

Z,,RF,, = (2.07 +- 0.01) kOhms

I,,d,, = (24.7 +- 0.6) mA

chi^2^ / ndf = 42

== RF Behavior with No Light ==

attachment:timeseries.png

attachment:dark_spectrum.png

== Picture of Photodiode ==

attachment:POX.jpg

Picture taken on 12/13/2010.

POX

The data for the following measurements is located at [https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/RFphotodiodes/POX/ /svn/trunk/docs/upgrade08/RFsystem/RFphotodiodes/POX/]

RF Transimpedance

attachment:transimpedance.png

The resonance peaks at 11, 22, and 55 MHz were measured in detail and fit to a resonance curve (see below) with the following results

Resonance Frequency

Transimpedance at Resonance

Q

(11.14 +- 0.01) MHz

(2.206 +- 0.001) kOhms

14.58 +- 0.01

(22.68 +- 0.01) MHz

(9.681 +- 0.003) Ohms

27.66 +- 0.01

(55.29 +- 0.01) MHz

(475 +- 2) mOhms

31.81 +- 0.05

Fits To Resonance

11 MHz Resonance

attachment:res1.png

f0 = (11.14 +- 0.01) MHz Gamma = (764 +- 1) kHz R0 = (8.38 +- 0.01) x 108 Hz Ohms C = (11.14 +- 0.05) Ohms chi^2/ndf = 95.4

22 MHz Resonance

attachment:res2.png

55 MHz Resonance

attachment:res3.png

Noise

attachment:noise.png

The noise data was fit to attachment:fitfunc.png with the following results:

ZRF = (2.07 +- 0.01) kOhms

Id = (24.7 +- 0.6) mA

chi2 / ndf = 42

RF Behavior with No Light

attachment:timeseries.png

attachment:dark_spectrum.png

Picture of Photodiode

attachment:POX.jpg

Picture taken on 12/13/2010.