This page is a summary of IFO Simulation Results using SIS. All of the codes to run the simulations are in the SVN in SIS/40m/.


Table of Contents


What is SIS?

Static Interferometer Simulation. FFT based field simulation written by Hiro Yamamoto. Manual is in the DCC.

Results

X Arm

So far, just using the ITM04 HR phase map:

ITMU04

The result is that the diffractive loss is ~0.5 ppm. The total scatter loss is ~4 ppm. So why do we see more like 100 ppm???

This is the 'summary' dump from SIS: {{{cavity length = 5.4156153590591e-08 = 5.4304550698212e-08(delL) - 0(ITMz) - 1.4839710762035e-10(ETMz) power in cavity = 286.27328293106, reflected power = 0.99517823839521, leakPower / Power00 = 0.99517823839521 / 0.99484788138773 Diffractive loss = 0.47823454052409, total loss = 4.3779597155291

++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

ROC(ITM) = 51380, ROC(ETM) = 59.5, Cavity lenggth = 38.49999944, total Gouy = 0.93494098230936 Fval(ITM) = -72926.229047965, OPL(ITM) = 0.13793033055886, Fval(ETM) = -132.22222240828 waist size = 0.0031035077771509, waist position from ITM = 0.015741056390046, Rayleigh range = 28.438973777894

Mode parameters of cavity fields ETM AR (out base) : w = 0.005222025 R = 41.03448 z = 32.57398 z0 = 16.60097 w0 = 0.00237117

ETM HR (in base) : w = 0.005222025 R = 59.5 z = 38.48426 z0 = 28.43897 w0 = 0.003103508

ITM HR (in base) : w = 0.003103508 R = 51380 z = 0.01574106 z0 = 28.43897 w0 = 0.003103508

ITM AR (in base) : w = 0.003103508 R = -35434.48 z = -0.02282452 z0 = 28.43896 w0 = 0.003103507


}}}

Core_Optics/Simulations (last edited 2012-01-03 23:02:41 by localhost)