= Calibration = I'm working on a simple model of the differential arm length sensing and control loop to guide work on real-time calibration. The model is based on Figure 6-1 in Rana's thesis. We will start tests for a real-time calibration system on one of the 40 m arm cavities using the digital control system. - Eric Hendries = Calibration Using Green = [[Calibration/SoCal]] === OSEMs === The rough calibration of the OSEMs we have now (2009 - the Adhikari/Fritschel OSEMs from 1999) is 2V/mm. <
> Then the signal gets whitened in hardware with a 30,100:3 (poles:zeros) whitening filter with a gain of 1 at DC. <
> The ADC calibration is then 16384 cts/V. <
> === Seismometers === === Magnetometers === === Steve ===