||<^>YEC||<^>10||<^>1||<^>default||<^>16k||<^>1||<^>1||<^>megatron||<^>ETMY suspension controller for use with the simulated plant YEP||
||<^>YEP||<^>11||<^>5||<^>3||<^>16k||<^>1||<^>1||<^>megatron||<^>ETMY suspension plant simulation, for use with YEC||
||<style="vertical-align: top;">YEC ||<style="vertical-align: top;">10 ||<style="vertical-align: top;">1 ||<style="vertical-align: top;">default ||<style="vertical-align: top;">16k ||<style="vertical-align: top;">1 ||<style="vertical-align: top;">1 ||<style="vertical-align: top;">megatron ||<style="vertical-align: top;">ETMY suspension controller for use with the simulated plant YEP ||
||<style="vertical-align: top;">YEP ||<style="vertical-align: top;">11 ||<style="vertical-align: top;">5 ||<style="vertical-align: top;">3 ||<style="vertical-align: top;">16k ||<style="vertical-align: top;">1 ||<style="vertical-align: top;">1 ||<style="vertical-align: top;">megatron ||<style="vertical-align: top;">ETMY suspension plant simulation, for use with YEC ||
||<^>MEM||<^>12||<^>4||<^>4||<^>16k||<^>1||<^>1||<^>megatron||<^>Acts as memory loop for YEP, allowing current position to feed back||

Name

dcuid

gds_node_id

specific_cpu

Sampling Rate

Shmem_daq

No_oversampling

Machine

Notes

OMC

30

4

default

32k

default

default

c1omc

Output mode cleaner control

ASS

22

default

default

2k

default

default

c1ass

Alignment Sensing & Stabilization - Adaptive Wiener filtering

TST

10

1

default

16k

1

1

megatron

ETMY suspension controller, testbed

MDC

12

4

default

16k

1

1

megatron

Original test controller for ETMY running simulated plant.

MDP

11

5

3

16k

1

1

megatron

Original test plant for ETMY.

TMC

12

4

default

16k

1

1

megatron

Generic test controller for switch from real world to simulated plant.

TMT

11

5

3

16k

1

1

megatron

Generic test plant for switch from real world to simulated plant.

YEC

10

1

default

16k

1

1

megatron

ETMY suspension controller for use with the simulated plant YEP

YEP

11

5

3

16k

1

1

megatron

ETMY suspension plant simulation, for use with YEC

MEM

12

4

4

16k

1

1

megatron

Acts as memory loop for YEP, allowing current position to feed back

/!\ This is correct as of March 26th, 2010.