1X1
c1ioo chassis
- Trenton BPX6806 506806, 18 slot PCIe backplane
Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071]
- Connects to IO chassis interface
Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3]
2 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual]
- ADC 0 is in slot 1, and connects to ADC Adapter Board in slot 1
- ADC 1 is in slot 2 and connects to ADC Adapter Board in slot 2
2 ADL General Standards 16 bit ADC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006]
1 DAC PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual]
- DAC 0 is in slot 3 and connects to DAC Adapter Board in slot 3
1 ADL General Standards 16 bit DAC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1]
1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- This is in slot 16 and connects to IO chassis Interface
1 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- BO0 is in slot 8
1X2
c1ioo computer. See CDS Map/c1ioo
Runs c1x03 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x03_slwebview_files/index.html webview]
Runs c1ioo front end model. [https://nodus.ligo.caltech.edu:30889/FE/c1ioo_slwebview_files/index.html webview]