Differences between revisions 4 and 8 (spanning 4 versions)
Revision 4 as of 2011-01-13 21:08:21
Size: 2136
Comment:
Revision 8 as of 2011-01-27 22:01:44
Size: 5250
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
= Racks' Map = = CDS Map =
Line 5: Line 5:
|| . || ||<|16> attachment:yarm.png|| ''''' Yarm ''''' ||
|| . || || ||
||[#1Y4 1Y4] || attachment:rack.png|| ||
|| . || || ||
|| . || || ||
|| . || || ||
|| . || || ||
|| . || || ||
|| . || || ||
|| . || || ||
|| [#1Y3 1Y3] || attachment:rack.png|| ||
|| [#1Y2 1Y2]|| attachment:rack.png|| ||
|| . || || ||
|| [#1Y1 1Y1]||attachment:rack.png || ||
|| . || || || || || || || || || || || [#1X8 1X8]|| attachment:rack.png || || ''''' Xarm '''''||
|| . || ||<-30> attachment:xarm.png ||
|| [#OMC OMC] || attachment:rack.png|| || attachment:rack.png ||attachment:rack.png || ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png || || || ||attachment:rack.png || ||
|| || || || [#1X1 1X1] || [#1X2 1X2] || - - || [#1X3 1X3] || [#1X4 1X4]|| [#1X5 1X5] || [#1X6 1X6]|| [#1X7 1X7]|| - - || - - || - - || [#1X9 1X9]|| - - ||
|| || || || c1ioo IO || c1ioo FE || - - || [#1X3 1X3] || [#1X4 1X4]|| [#1X5 1X5] || [#1X6 1X6]|| [#1X7 1X7]|| - - || - - || - - || [#1X9 1X9]|| - - ||
|| . || . || ||<|16> attachment:yarm.png|| ''''' Yarm ''''' ||
|| . || . || || ||
||[#c1iscexIOFE c1iscex IO/FE] || [#1Y4 1Y4] || attachment:rack.png|| ||
|| . || . || || ||
|| . || . || || ||
|| . || . || || ||
|| . || . || || ||
|| [#c1lscIOFE c1lsc IO/FE] || [#1Y3 1Y3] || attachment:rack.png|| ||
|| . || [#1Y2 1Y2]|| attachment:rack.png|| ||
|| . || . || || ||
|| . || [#1Y1 1Y1]||attachment:rack.png || ||
|| . || [#OMC OMC] || attachment:rack.png||
|| . || . || || ||
|| . || . || || || || || || || || || || [#1X8 1X8]|| attachment:rack.png || ''''' Xarm '''''||
|| . || . || ||<-30> attachment:xarm.png ||
|| . || . || ||attachment:rack.png ||attachment:rack.png || ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png || attachment:rack.png || ||attachment:rack.png || ||
|| . || || || || [#1X1 1X1] || [#1X2 1X2] || - - || [#1X3 1X3] || [#1X4 1X4]|| [#1X5 1X5] || [#1X6 1X6]|| [#1X7 1X7]|| - - || [#1X9 1X9]|| - - ||
|| . || || || || [#c1iooIO c1ioo IO] || [#c1iooFE c1ioo FE] || - - || - - || [#c1susIOFE c1sus IO/FE] || - - || [#fb framebuilder] || - - || - - || [#c1iscexIOFE c1iscex IO/FE] || - - ||
Line 31: Line 30:
 A. '''c1ioo''' chassis
  1. 2 ADCs PMC66-16AI6455A-64-50M
<<Anchor(c1iooIO)>>
 A. '''c1ioo''' IO chassis

  1. Trenton BPX6806 506806, 18 slot PCIe backplane
  1. Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071]
    a. Connects to IO chassis interface
  1. Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3]
  1. 2 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual]
Line 35: Line 40:
  1. 2 Advanced LIGO ADL General Standards 16 bit ADC Adapter Board (D0902006)
  1. 1 DAC PMC66-16AO16-16-F0-OF
  1. 2 ADL General Standards 16 bit ADC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006]
  1. 1 DAC PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual]
Line 38: Line 43:
  1. 1 Contec DIO-1616L-PE Isolated Digital IO board   1. 1 ADL General Standards 16 bit DAC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1]
  1. 1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
Line 40: Line 46:
  1. 1 Contec DO-32L-PE Isolated Digital Output Board   1. 1 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
Line 42: Line 48:
  1. Timing Board, DCC #: D070071
   a. This connects to IO chassis interface
  1. Trenton BPX6806 506806, 18 slot PCIe backplane
  1. Advanced LIGO IO Chassis Interface, DCC # D0902029-V3

All slots are listed as counting from the right, looking at the back of the chassis
  1. One Stop Sytems Host interface board OSS-MAX-EXP-ELB-C
   a. This is in the far right slot when looking at the back of the chassis. It connects to the c1ioo FE computer.
Line 51: Line 53:
 A. '''c1ioo''' computer
  1. Runs '''c1x04''' IOP (input output processor)
  1. Runs '''c1ioo''' front end model
<<Anchor(ciooFE)>>
 A. '''c1ioo''' FE computer. See [[CDS Map/c1ioo]]
  1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]
    a. This connects to the Reflected memory network hub in rack [#1X7 1X7].
  1. One Stop Systems Host interface card OSS-PCIe-HIB2-x4-H [http://www.onestopsystems.com/documents/OSS-PCIe-HIB2-x4-H-T_003.pdf Manual]
    a. This connects to the c1ioo IO chassis.
  1. Runs '''c1x03''' IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x03_slwebview_files/index.html webview]
  1. Runs '''c1ioo''' front end model. Input Output Optics [https://nodus.ligo.caltech.edu:30889/FE/c1ioo_slwebview_files/index.html webview]

<<Anchor(1X3)>>
== 1X3 ==

<<Anchor(1X4)>>
== 1X4 ==
<<Anchor(c1susIOFE)>>
 A. '''c1sus''' IO chassis

 A. '''c1sus''' FE chassis. See [[CDS Map/c1sus]]
  1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]
    a. This connects to the Reflected memory network hub in rack [#1X7 1X7].
  1. Dolphin DXH510 PCI Express Host Adapter
    a. This connects to the Dolphin DXS410 dx 10 Port Switch in rack [#1X4 1X4]
  1. Runs '''c1x02''' IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x02_slwebview_files/index.html webview]
  1. Runs '''c1sus''' front end model. Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
  1. Runs '''c1mcs''' front end model. Mode Cleaner Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
  1. Runs '''c1rfm''' front end model. Reflected memory. [https://nodus.ligo.caltech.edu:30889/FE/c1rfm_slwebview_files/index.html webview]
  1. Runs '''c1pem''' front end model. Physical Environment Monitor. [https://nodus.ligo.caltech.edu:30889/FE/c1pem_slwebview_files/index.html webview]

 A. Dolphin DXS410 dx 10 Port Switch
    a. Connects to c1sus FE computer in [#1X4 1X4] and via fiber to the c1lsc FE computer in rack [#1Y3 1Y3]

<<Anchor(1X5)>>
== 1X5 ==

<<Anchor(1X6)>>
== 1X6 ==

<<Anchor(1X7)>>
== 1X7 ==

<<Anchor(1X8)>>
== 1X8 ==

<<Anchor(1X9)>>
== 1X9 ==

<<Anchor(1Y1)>>
== 1Y1 ==

<<Anchor(1Y2)>>
== 1Y2 ==

<<Anchor(1Y3)>>
== 1Y3 ==

<<Anchor(1Y4)>>
== 1Y4 ==

Still under construction

CDS Map

.

.

attachment:yarm.png

Yarm

.

.

[#c1iscexIOFE c1iscex IO/FE]

[#1Y4 1Y4]

attachment:rack.png

.

.

.

.

.

.

.

.

[#c1lscIOFE c1lsc IO/FE]

[#1Y3 1Y3]

attachment:rack.png

.

[#1Y2 1Y2]

attachment:rack.png

.

.

.

[#1Y1 1Y1]

attachment:rack.png

.

[#OMC OMC]

attachment:rack.png

.

.

.

.

[#1X8 1X8]

attachment:rack.png

Xarm

.

.

attachment:xarm.png

.

.

attachment:rack.png

attachment:rack.png

attachment:rack.png

attachment:rack.png

attachment:rack.png

attachment:rack.png

attachment:rack.png

attachment:rack.png

.

[#1X1 1X1]

[#1X2 1X2]

- -

[#1X3 1X3]

[#1X4 1X4]

[#1X5 1X5]

[#1X6 1X6]

[#1X7 1X7]

- -

[#1X9 1X9]

- -

.

[#c1iooIO c1ioo IO]

[#c1iooFE c1ioo FE]

- -

- -

[#c1susIOFE c1sus IO/FE]

- -

[#fb framebuilder]

- -

- -

[#c1iscexIOFE c1iscex IO/FE]

- -

Art courtesy of Kiwamu BR BR

1X1

  1. c1ioo IO chassis

    1. Trenton BPX6806 506806, 18 slot PCIe backplane
    2. Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071]

      1. Connects to IO chassis interface
    3. Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3]

    4. 2 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual]

      1. ADC 0 is in slot 1, and connects to ADC Adapter Board in slot 1
      2. ADC 1 is in slot 2 and connects to ADC Adapter Board in slot 2
    5. 2 ADL General Standards 16 bit ADC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006]

    6. 1 DAC PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual]

      1. DAC 0 is in slot 3 and connects to DAC Adapter Board in slot 3
    7. 1 ADL General Standards 16 bit DAC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1]

    8. 1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]

      1. This is in slot 16 and connects to IO chassis Interface
    9. 1 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]

      1. BO0 is in slot 8
    10. One Stop Sytems Host interface board OSS-MAX-EXP-ELB-C
      1. This is in the far right slot when looking at the back of the chassis. It connects to the c1ioo FE computer.

1X2

  1. c1ioo FE computer. See CDS Map/c1ioo

    1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]

      1. This connects to the Reflected memory network hub in rack [#1X7 1X7].
    2. One Stop Systems Host interface card OSS-PCIe-HIB2-x4-H [http://www.onestopsystems.com/documents/OSS-PCIe-HIB2-x4-H-T_003.pdf Manual]

      1. This connects to the c1ioo IO chassis.
    3. Runs c1x03 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x03_slwebview_files/index.html webview]

    4. Runs c1ioo front end model. Input Output Optics [https://nodus.ligo.caltech.edu:30889/FE/c1ioo_slwebview_files/index.html webview]

1X3

1X4

  1. c1sus IO chassis

  2. c1sus FE chassis. See CDS Map/c1sus

    1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]

      1. This connects to the Reflected memory network hub in rack [#1X7 1X7].
    2. Dolphin DXH510 PCI Express Host Adapter
      1. This connects to the Dolphin DXS410 dx 10 Port Switch in rack [#1X4 1X4]
    3. Runs c1x02 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x02_slwebview_files/index.html webview]

    4. Runs c1sus front end model. Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]

    5. Runs c1mcs front end model. Mode Cleaner Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]

    6. Runs c1rfm front end model. Reflected memory. [https://nodus.ligo.caltech.edu:30889/FE/c1rfm_slwebview_files/index.html webview]

    7. Runs c1pem front end model. Physical Environment Monitor. [https://nodus.ligo.caltech.edu:30889/FE/c1pem_slwebview_files/index.html webview]

  3. Dolphin DXS410 dx 10 Port Switch
    1. Connects to c1sus FE computer in [#1X4 1X4] and via fiber to the c1lsc FE computer in rack [#1Y3 1Y3]

1X5

1X6

1X7

1X8

1X9

1Y1

1Y2

1Y3

1Y4

CDS/CDS_Map (last edited 2012-01-03 23:02:38 by localhost)