| = Racks' Map = | = CDS Map = |
| Line 5: | Line 5: |
| || . || ||<|16> attachment:yarm.png|| ''''' Yarm ''''' || || . || || || ||[#1Y4 1Y4] || attachment:rack.png|| || || . || || || || . || || || || . || || || || . || || || || . || || || || . || || || || . || || || || [#1Y3 1Y3] || attachment:rack.png|| || || [#1Y2 1Y2]|| attachment:rack.png|| || || . || || || || [#1Y1 1Y1]||attachment:rack.png || || || . || || || || || || || || || || || [#1X8 1X8]|| attachment:rack.png || || ''''' Xarm '''''|| || . || ||<-30> attachment:xarm.png || || [#OMC OMC] || attachment:rack.png|| || attachment:rack.png ||attachment:rack.png || ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png || || || ||attachment:rack.png || || || || || || [#1X1 1X1] || [#1X2 1X2] || - - || [#1X3 1X3] || [#1X4 1X4]|| [#1X5 1X5] || [#1X6 1X6]|| [#1X7 1X7]|| - - || - - || - - || [#1X9 1X9]|| - - || |
|| . || . || ||<|16> attachment:yarm.png|| ''''' Yarm ''''' || || . || . || || || ||[#c1iscexIOFE c1iscex IO/FE] || [#1Y4 1Y4] || attachment:rack.png|| || || . || . || || || || . || . || || || || . || . || || || || . || . || || || || [#c1lscIOFE c1lsc IO/FE] || [#1Y3 1Y3] || attachment:rack.png|| || || . || [#1Y2 1Y2]|| attachment:rack.png|| || || . || . || || || || . || [#1Y1 1Y1]||attachment:rack.png || || || . || [#OMC OMC] || attachment:rack.png|| || . || . || || || || . || . || || || || || || || || || || [#1X8 1X8]|| attachment:rack.png || ''''' Xarm '''''|| || . || . || ||<-30> attachment:xarm.png || || . || . || ||attachment:rack.png ||attachment:rack.png || ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png ||attachment:rack.png || attachment:rack.png || ||attachment:rack.png || || || . || || || || [#1X1 1X1] || [#1X2 1X2] || - - || [#1X3 1X3] || [#1X4 1X4]|| [#1X5 1X5] || [#1X6 1X6]|| [#1X7 1X7]|| - - || [#1X9 1X9]|| - - || || . || || || || [#c1iooIO c1ioo IO] || [#c1iooFE c1ioo FE] || - - || - - || [#c1susIOFE c1sus IO/FE] || - - || [#fb framebuilder] || - - || - - || [#c1iscexIOFE c1iscex IO/FE] || - - || |
| Line 30: | Line 30: |
| A. '''c1ioo''' chassis 1. 2 ADCs PMC66-16AI6455A-64-50M a. ADC 0 is in slot 1 a. ADC 1 is in slot 3 1. 1 DAC PMC66-16AO16-16-F0-OF a. DAC 0 is in slot 2 1. 1 Contec DIO-1616L-PE Isolated Digital IO board 1. 1 Contec DO-32L-PE Isolated Digital Output Board a. BO0 is in slot 4 1. Timing Board, DCC #: D070071 1. Trenton BPX6806 506806, 18 slot PCIe backplane |
<<Anchor(c1iooIO)>> A. '''c1ioo''' IO chassis |
| Line 42: | Line 33: |
| All slots are listed as counting from the right, looking at the back of the chassis | 1. Trenton BPX6806 506806, 18 slot PCIe backplane 1. Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071] a. Connects to IO chassis interface 1. Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3] 1. 2 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual] a. ADC 0 is in slot 1, and connects to ADC Adapter Board in slot 1 a. ADC 1 is in slot 2 and connects to ADC Adapter Board in slot 2 1. 2 ADL General Standards 16 bit ADC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006] 1. 1 DAC PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual] a. DAC 0 is in slot 3 and connects to DAC Adapter Board in slot 3 1. 1 ADL General Standards 16 bit DAC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1] 1. 1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual] a. This is in slot 16 and connects to IO chassis Interface 1. 1 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual] a. BO0 is in slot 8 1. One Stop Sytems Host interface board OSS-MAX-EXP-ELB-C a. This is in the far right slot when looking at the back of the chassis. It connects to the c1ioo FE computer. |
| Line 46: | Line 53: |
| A. '''c1ioo''' computer 1. Runs '''c1x04''' IOP (input output processor) 1. Runs '''c1ioo''' front end model |
<<Anchor(ciooFE)>> A. '''c1ioo''' FE computer. See [[CDS Map/c1ioo]] 1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual] a. This connects to the Reflected memory network hub in rack [#1X7 1X7]. 1. One Stop Systems Host interface card OSS-PCIe-HIB2-x4-H [http://www.onestopsystems.com/documents/OSS-PCIe-HIB2-x4-H-T_003.pdf Manual] a. This connects to the c1ioo IO chassis. 1. Runs '''c1x03''' IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x03_slwebview_files/index.html webview] 1. Runs '''c1ioo''' front end model. Input Output Optics [https://nodus.ligo.caltech.edu:30889/FE/c1ioo_slwebview_files/index.html webview] <<Anchor(1X3)>> == 1X3 == <<Anchor(1X4)>> == 1X4 == <<Anchor(c1susIOFE)>> A. '''c1sus''' IO chassis A. '''c1sus''' FE chassis. See [[CDS Map/c1sus]] 1. GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual] a. This connects to the Reflected memory network hub in rack [#1X7 1X7]. 1. Dolphin DXH510 PCI Express Host Adapter a. This connects to the Dolphin DXS410 dx 10 Port Switch in rack [#1X4 1X4] 1. Runs '''c1x02''' IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x02_slwebview_files/index.html webview] 1. Runs '''c1sus''' front end model. Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview] 1. Runs '''c1mcs''' front end model. Mode Cleaner Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview] 1. Runs '''c1rfm''' front end model. Reflected memory. [https://nodus.ligo.caltech.edu:30889/FE/c1rfm_slwebview_files/index.html webview] 1. Runs '''c1pem''' front end model. Physical Environment Monitor. [https://nodus.ligo.caltech.edu:30889/FE/c1pem_slwebview_files/index.html webview] A. Dolphin DXS410 dx 10 Port Switch a. Connects to c1sus FE computer in [#1X4 1X4] and via fiber to the c1lsc FE computer in rack [#1Y3 1Y3] <<Anchor(1X5)>> == 1X5 == <<Anchor(1X6)>> == 1X6 == <<Anchor(1X7)>> == 1X7 == <<Anchor(1X8)>> == 1X8 == <<Anchor(1X9)>> == 1X9 == <<Anchor(1Y1)>> == 1Y1 == <<Anchor(1Y2)>> == 1Y2 == <<Anchor(1Y3)>> == 1Y3 == <<Anchor(1Y4)>> == 1Y4 == |
Still under construction
CDS Map
. |
. |
|
attachment:yarm.png |
Yarm |
||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
[#c1iscexIOFE c1iscex IO/FE] |
[#1Y4 1Y4] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
[#c1lscIOFE c1lsc IO/FE] |
[#1Y3 1Y3] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
[#1Y2 1Y2] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
[#1Y1 1Y1] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
[#OMC OMC] |
attachment:rack.png |
||||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|
|
|
|
|
|
|
[#1X8 1X8] |
attachment:rack.png |
Xarm |
|||||||||||||||||||
. |
. |
|
attachment:xarm.png |
|||||||||||||||||||||||||||||
. |
. |
|
attachment:rack.png |
attachment:rack.png |
|
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
|
attachment:rack.png |
|
|||||||||||||||||||
. |
|
|
|
[#1X1 1X1] |
[#1X2 1X2] |
- - |
[#1X3 1X3] |
[#1X4 1X4] |
[#1X5 1X5] |
[#1X6 1X6] |
[#1X7 1X7] |
- - |
[#1X9 1X9] |
- - |
||||||||||||||||||
. |
|
|
|
[#c1iooIO c1ioo IO] |
[#c1iooFE c1ioo FE] |
- - |
- - |
[#c1susIOFE c1sus IO/FE] |
- - |
[#fb framebuilder] |
- - |
- - |
[#c1iscexIOFE c1iscex IO/FE] |
- - |
||||||||||||||||||
1X1
c1ioo IO chassis
- Trenton BPX6806 506806, 18 slot PCIe backplane
Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071]
- Connects to IO chassis interface
Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3]
2 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual]
- ADC 0 is in slot 1, and connects to ADC Adapter Board in slot 1
- ADC 1 is in slot 2 and connects to ADC Adapter Board in slot 2
2 ADL General Standards 16 bit ADC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006]
1 DAC PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual]
- DAC 0 is in slot 3 and connects to DAC Adapter Board in slot 3
1 ADL General Standards 16 bit DAC Adapter Board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1]
1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- This is in slot 16 and connects to IO chassis Interface
1 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- BO0 is in slot 8
- One Stop Sytems Host interface board OSS-MAX-EXP-ELB-C
- This is in the far right slot when looking at the back of the chassis. It connects to the c1ioo FE computer.
1X2
c1ioo FE computer. See CDS Map/c1ioo
GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]
- This connects to the Reflected memory network hub in rack [#1X7 1X7].
One Stop Systems Host interface card OSS-PCIe-HIB2-x4-H [http://www.onestopsystems.com/documents/OSS-PCIe-HIB2-x4-H-T_003.pdf Manual]
- This connects to the c1ioo IO chassis.
Runs c1x03 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x03_slwebview_files/index.html webview]
Runs c1ioo front end model. Input Output Optics [https://nodus.ligo.caltech.edu:30889/FE/c1ioo_slwebview_files/index.html webview]
1X3
1X4
c1sus IO chassis
c1sus FE chassis. See CDS Map/c1sus
GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]
- This connects to the Reflected memory network hub in rack [#1X7 1X7].
- Dolphin DXH510 PCI Express Host Adapter
- This connects to the Dolphin DXS410 dx 10 Port Switch in rack [#1X4 1X4]
Runs c1x02 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x02_slwebview_files/index.html webview]
Runs c1sus front end model. Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
Runs c1mcs front end model. Mode Cleaner Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
Runs c1rfm front end model. Reflected memory. [https://nodus.ligo.caltech.edu:30889/FE/c1rfm_slwebview_files/index.html webview]
Runs c1pem front end model. Physical Environment Monitor. [https://nodus.ligo.caltech.edu:30889/FE/c1pem_slwebview_files/index.html webview]
- Dolphin DXS410 dx 10 Port Switch
- Connects to c1sus FE computer in [#1X4 1X4] and via fiber to the c1lsc FE computer in rack [#1Y3 1Y3]
1X5
1X6
1X7
1X8
1X9