| ||[#c1isceyIOFE c1iscex IO/FE] || [#1Y4 1Y4] || attachment:rack.png|| || | ||[#c1isceyIOFE c1iscey IO/FE] || [#1Y4 1Y4] || attachment:rack.png|| || |
Still under construction
CDS Map
. |
. |
|
attachment:yarm.png |
Yarm |
||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
[#c1isceyIOFE c1iscey IO/FE] |
[#1Y4 1Y4] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
[#c1lscIOFE c1lsc IO/FE] |
[#1Y3 1Y3] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
[#1Y2 1Y2] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
[#1Y1 1Y1] |
attachment:rack.png |
|
|||||||||||||||||||||||||||||
. |
[#OMC OMC] |
|
||||||||||||||||||||||||||||||
. |
. |
|
|
|||||||||||||||||||||||||||||
. |
. |
|
|
|
|
|
|
|
|
|
[#1X8 1X8] |
attachment:rack.png |
Xarm |
|||||||||||||||||||
. |
. |
|
attachment:xarm.png |
|||||||||||||||||||||||||||||
. |
. |
|
attachment:rack.png |
attachment:rack.png |
|
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
attachment:rack.png |
|
attachment:rack.png |
|
|||||||||||||||||||
. |
|
|
|
[#1X1 1X1] |
[#1X2 1X2] |
- - |
[#1X3 1X3] |
[#1X4 1X4] |
[#1X5 1X5] |
[#1X6 1X6] |
[#1X7 1X7] |
- - |
[#1X9 1X9] |
- - |
||||||||||||||||||
. |
|
|
|
[#c1iooIO c1ioo IO] |
[#c1iooFE c1ioo FE] |
- - |
- - |
c1sus [#c1susIO IO]/[#c1susFE FE] |
- - |
[#fb fb] |
- - |
- - |
[#c1iscexIOFE c1iscex IO/FE] |
- - |
||||||||||||||||||
Useful Diagrams
attachment:NetworkTopology.pdf
1X1
c1ioo IO chassis. See CDS Map/c1iooIOchassis
1X2
c1ioo FE computer. Runs c1x03, c1ioo, c1gcv. See CDS Map/c1ioo
1X3
1X4
c1sus IO chassis. See CDS Map/c1susIOchassis
- Trenton BPX6806 506806, 18 slot PCIe backplane
Timing board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=7093 D070071]
- Connects to IO chassis interface
Advanced LIGO IO chassis Interface board [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5250 D0902029-V3]
4 ADCs PMC66-16AI6455A-64-50M [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc16ai64_man_090406.pdf Manual]
- ADC 0 is in slot 1, and connects to ADC Adapter Board in slot 3
- ADC 1 is in slot 4 and connects to ADC Adapter Board in slot 5
- ADC 2 is in slot 3 and connects to ADC Adapter board in slot 4
- ADC 3 is in slot 5 and connects to ADC Adapter board in slot 6
4 ADL General Standards 16 bit ADC Adapter Boards [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=5190 D0902006]
- ADC 0 adapter board in slot 3 connects to top anti-aliasing chassis in rack [#1X5 1X5].
- ADC 1 adapter board in slot 5 connects to bottom Anti-aliasing chassis in rack [#1X5 1X5].
- ADC 2 adapter board in slot 4 connects to DB37 to ADC SCSI Adapter D080302
- ADC 3 adapter board in slot 6 connects to anti-aliasing chassis in rack [#1X7 1X7]
3 DACs PMC66-16AO16-16-F0-OF [http://www.generalstandards.com/download.php?catid=usermanual&file=pmc66_16ao16_man_090406.pdf Manual]
- DAC 0 is in slot 2 and connects to DAC Adapter Board in slot 2
- DAC 1 is in slot 11 and connects to DAC Adapter Board in slot 11
- DAC 2 is in slot 10 and connects to DAC Adapter Board in slot 10
3 ADL General Standards 16 bit DAC Adapter Boards [https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=6787 D0902496-v1]
- DAC 0 adapter board in slot 2 connects to top most DAC to IDC adapter D080303 in rack [#1X5 1X5]
- DAC 1 adapter board in slot 11 connects to middle DAC to IDC adapter D080303 in rack [#1X5 1X5]
- DAC 2 adapter board in slot 10 connects to bottom DAC to IDC adapter D080303 in rack [#1X5 1X5]
1 Contec DIO-1616L-PE Isolated Digital IO board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- This is in slot 16 and connects to IO chassis Interface
4 Contec DO-32L-PE Isolated Digital Output Board [http://www.contec.com/products/dlrank/dlranklog.cgi?dl=DIO-1616L-PE:LYFY76:1/1 Manual]
- BO0 is in slot 9 and connects to top most Binary IO adapter in rack [#1X5 1X5]
- BO1 is in slot 8 and connects to 2nd from the top Binary IO adapter in rack [#1X5 1X5]
- BO2 is in slot 7 and connects to 3rd from the top Binary IO adapter in rack [#1X5 1X5]
- BO3 is in slot 6 and connects to bottom Binary IO adapter in rack [#1X5 1X5]
- One Stop Systems expansion link board OSS-MAX-EXP-ELB-C
- This is in the far right slot when looking at the back of the chassis. It connects to the [#c1susFE c1sus FE] computer.
c1sus FE chassis. 6 processors. See CDS Map/c1susFEcomputer
GE Fanuc VMIC 5565 with PMC to PCI adapter board [http://defense.ge-ip.com/account/download/1881/1286 Manual]
- This connects to the Reflected memory network hub in rack [#1X7 1X7].
- Dolphin DXH510 PCI Express Host Adapter
- This connects to the Dolphin DXS410 dx 10 Port Switch in rack [#1X4 1X4]
- One Stop Systems host interface board OSS-PCIe-HIB2-x4-H
- This connects to the [#c1susIO c1sus IO] chassis.
Runs c1x02 IOP (input output processor). [https://nodus.ligo.caltech.edu:30889/FE/c1x02_slwebview_files/index.html webview]
Runs c1sus front end model. Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
Runs c1mcs front end model. Mode Cleaner Suspensions. [https://nodus.ligo.caltech.edu:30889/FE/c1sus_slwebview_files/index.html webview]
Runs c1rfm front end model. Reflected memory. [https://nodus.ligo.caltech.edu:30889/FE/c1rfm_slwebview_files/index.html webview]
Runs c1pem front end model. Physical Environment Monitor. [https://nodus.ligo.caltech.edu:30889/FE/c1pem_slwebview_files/index.html webview]
- Dolphin DXS410 dx 10 Port Switch
- Connects to c1sus FE computer in [#1X4 1X4] and via fiber to the c1lsc FE computer in rack [#1Y3 1Y3]
1X5
1X6
1X7
1X8