Differences between revisions 2 and 14 (spanning 12 versions)
Revision 2 as of 2017-10-27 04:50:45
Size: 14
Comment:
Revision 14 as of 2019-04-05 00:51:26
Size: 1039
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
Noise Budget = Balanced Homodyne Detection =


==== Requirements ====
 1. Displacement noise of OMC/LMC mirrors
 1. Scatter loss in mirrors
 1. Cavity design: triangle, quad ring, quad zig-zag (reference the new OMC paper from Koj)
 1. Laser amplitude / frequency noise including DC offsets in various other lock points and motions to simulate bilinear noise
 1. Oscillator noise: AM / FM
 1. Aux length noise: MICH/PRC/ SRC
 1. Req. on offsets/asymmetries: arm finesse, arm reflectivity, mass imbalance of ETMs

==== Modelling/Noise Budget ====
 * Some BHD modeling is done in the OptimalGWextraction repo [[https://github.com/CaltechExperimentalGravity/OptimalGWextraction/tree/master/PonderSqueeze/BHD|here]].

==== Polarization BHD ====
 * [[https://dcc.ligo.org/LIGO-G1802013|Some thoughts on polarization BHD (LIGO-G1802013)]]
 * [[attachment:OMC.pdf|Polarization BHD notes]]

==== Other Links ====
 * [[https://wiki.ligo.org/AIC/BHD_A_plus|A+ BHD wiki]]
 * [[https://wiki.ligo.org/AIC/BHD_MIT_WS|MIT A+ BHD workshop wiki]]

Balanced Homodyne Detection

Requirements

  1. Displacement noise of OMC/LMC mirrors
  2. Scatter loss in mirrors
  3. Cavity design: triangle, quad ring, quad zig-zag (reference the new OMC paper from Koj)
  4. Laser amplitude / frequency noise including DC offsets in various other lock points and motions to simulate bilinear noise
  5. Oscillator noise: AM / FM
  6. Aux length noise: MICH/PRC/ SRC
  7. Req. on offsets/asymmetries: arm finesse, arm reflectivity, mass imbalance of ETMs

Modelling/Noise Budget

  • Some BHD modeling is done in the OptimalGWextraction repo here.

Polarization BHD

Balanced Homodyne Detection (last edited 2020-04-29 17:41:39 by JonathanrichardsonATligoDOTorg)