Differences between revisions 63 and 65 (spanning 2 versions)
Revision 63 as of 2013-02-07 17:10:29
Size: 1386
Comment:
Revision 65 as of 2013-02-07 17:21:43
Size: 1488
Comment:
Deletions are marked like this. Additions are marked like this.
Line 23: Line 23:

Line 28: Line 30:

== 2" Dichroic Recycling Cavity Mirrors from Laseroptik, measurement data of 06-29-2012 ==


►Folding mirrors

We use 2inch mirrors (d2" x t3/8") mirrors for the PRC/SRC folding mirrors.

Their name has been changed such that the definition agrees with the AdvLIGO naming. (12/01/2009)

Specs of the folding mirrors (as of Dec 16, 2009)

Name

PR2

PR3

SR3

SR2

Size

2"dia. X 3/8" thick

2"dia. X 3/8" thick

2"dia. X 3/8" thick

2"dia. X 3/8" thick

Incident angle

2.5 deg

36.5 deg

44 deg

6 deg

HR Transmission 1064 nm

500ppm

< 100 ppm

< 100ppm

< 100ppm

AR Reflection 1064 nm

< 0.25%

< 0.25%

< 0.25%

< 0.25%

ROC

Flat

Flat

Flat

Flat

Wedge angle

1 deg

1 deg

1 deg

1 deg

Qty.

2

2

2

2

R for 532nm to be considered!

<!> At the installation in 2010, G&H HR mirrors were used for the TT mirrors. This results very little transmission through those mirrorrs (<25ppm).


2" Dichroic Recycling Cavity Mirrors from Laseroptik, measurement data of 06-29-2012

►Miscellaneous Optics (as of May 12, 2010)

Reflectivity and Transmissivity measurement for various mirrors with 523nm and 1064nm

Optical_Layout

40m_optics_list_upgrade_101214.png

40m_optics_list_upgrade_101214.pdf

40m_optics_list_upgrade_101214.xls