== Noise Requirements ==
I'd say the arm cavity length should not change more than 1/100 of the resonance width in the time scale of 10sec.
For this to be fulfilled, the RMS change of the cavity length must be suppressed below 1e-11m level.

== Noise Requirement ==
I'd say the arm cavity length should not change more than 1/100 of the resonance width in the time scale of 10sec.[[BR]]
For this to be fulfilled, the RMS fluctuation of the cavity length must be suppressed below 1e-11m level.[[BR]]
Line 10: Line 11:

=== Noise Sources ===
==== PLL phase noise ====
==== Phase noise from the cavity common mode motion ====

Green Laser Injection for Arm Pre-Lock

We plan to install green lasers, which are phase locked to the PSL laser, at each end station to pre-lock the arm cavities before the lock acquisition.

Basic Concept

Noise Requirement

I'd say the arm cavity length should not change more than 1/100 of the resonance width in the time scale of 10sec.BR For this to be fulfilled, the RMS fluctuation of the cavity length must be suppressed below 1e-11m level.BR Does this make sense ?

Noise Sources

PLL phase noise

Phase noise from the cavity common mode motion