|
Size: 199
Comment: u
|
Size: 618
Comment:
|
| Deletions are marked like this. | Additions are marked like this. |
| Line 4: | Line 4: |
== Basic Concept == == Noise Requirement == I'd say the arm cavity length should not change more than 1/100 of the resonance width in the time scale of 10sec.[[BR]] For this to be fulfilled, the RMS fluctuation of the cavity length must be suppressed below 1e-11m level.[[BR]] Does this make sense ? === Noise Sources === ==== PLL phase noise ==== ==== Phase noise from the cavity common mode motion ==== |
Green Laser Injection for Arm Pre-Lock
We plan to install green lasers, which are phase locked to the PSL laser, at each end station to pre-lock the arm cavities before the lock acquisition.
Basic Concept
Noise Requirement
I'd say the arm cavity length should not change more than 1/100 of the resonance width in the time scale of 10sec.BR For this to be fulfilled, the RMS fluctuation of the cavity length must be suppressed below 1e-11m level.BR Does this make sense ?
Noise Sources
PLL phase noise
