Size: 1996
Comment:
|
← Revision 20 as of 2012-01-03 23:02:39 ⇥
Size: 2103
Comment: converted to 1.6 markup
|
| Deletions are marked like this. | Additions are marked like this. |
| Line 14: | Line 14: |
| . attachment:PMAM_innolight.png | . {{attachment:PMAM_innolight.png}} |
| Line 19: | Line 19: |
| . attachment:temp_xend_psl.png | . {{attachment:temp_xend_psl.png}} |
| Line 23: | Line 23: |
| . Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. [http://nodus.ligo.caltech.edu:8080/40m/2794 Also, see the elog here]. | . Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. [[http://nodus.ligo.caltech.edu:8080/40m/2794|Also, see the elog here]]. |
| Line 29: | Line 29: |
| . <<ImageLink(innolight_temperature_sweep.png,Upgrade 09/GreenLock/Control Information/innolight_temperature_sweep,height=400)>> | . [[Upgrade 09/GreenLock/Control Information/innolight_temperature_sweep|{{attachment:innolight_temperature_sweep.png||height=400}}]] |
| Line 32: | Line 32: |
| [[BR]] [[BR]] [[BR]] |
<<BR>> <<BR>> <<BR>> |
| Line 48: | Line 48: |
| . attachment:PMAM_lightwave.png | . {{attachment:PMAM_lightwave.png}} |
| Line 52: | Line 52: |
| . attachment:temp_yend_psl_coarse.jpg | . {{attachment:temp_yend_psl_coarse.jpg}} |
| Line 55: | Line 55: |
| . attachment:temp_yend_psl.jpg | . {{attachment:temp_yend_psl.jpg}} |
| Line 63: | Line 63: |
| . Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. [http://nodus.ligo.caltech.edu:8080/40m/2794 Also, see the elog here]. | . Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. [[http://nodus.ligo.caltech.edu:8080/40m/2794|Also, see the elog here]]. |
| Line 69: | Line 69: |
| . <<ImageLink(lightwave_temperature_sweep.png,Upgrade 09/GreenLock/Control Information/lightwave_temperature_sweep,height=400)>> | . [[Upgrade 09/GreenLock/Control Information/lightwave_temperature_sweep|{{attachment:lightwave_temperature_sweep.png||height=400}}]] |
| Line 73: | Line 73: |
| [[BR]] | <<BR>> |
Contents
X end laser (Innolight)
Nominal Parameters
Innolight Mephisto
Part Number
Power
1 W
Nominal Current
2.0 A
Modulation Frequency fm
216.075 kHz
PM/AM ratio at fm
6e+5 [rad/RIN]
Modulations
Temperature and beatnote (PSL vs X end laser )
Laser Frequency vs Crystal Temperature
Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. Also, see the elog here.
Laser
df/dT
df/dV - within a mode
df/dV - average
Innolight
3.3MHz/mK
-
-
Y end laser (Lightwave)
Nominal Parameters
Lightwave
Part Number
Power
700m W (?)
Nominal Current
Modulation Frequency fm
-
PM/AM ratio at fm
-
Modulations
Temperature and beatnote (PSL vs Y end laser )
Coarse scan
Fine scan
Fitting results
- Y_arm_Temp_meas = 0.95152*T_PSL + 3.8672
- Y_arm_Temp_set = 0.87326*T_PSL + 6.9825
Laser Frequency vs Crystal Temperature
Plots of the laser frequency vs temperature (measured by beating against a second laser) are shown below. Also, see the elog here.
Laser
df/dT
df/dV - within a mode
df/dV - average
Lightwave
2.8MHz/mK
5GHz/V
1.6GHz/V