Line 15: Line 15:
== Description ==  == Description ==
Line 17: Line 17:
The PSL laser is locked to the arm cavity using the PDH error signal. The green laser is injected from the ETM side of the arm. The relative phase between the two lasers is kept constant using a phase-locked-loop (PLL) servo. The transmitted end-green from the arm interferes with the frequency-doubled PSL and produce a beatnote. The PSL laser is locked to the arm cavity using the PDH error signal. The green laser is injected from the ETM side of the arm. The relative phase between the two lasers is kept constant using a phase-locked-loop (PLL) servo. The transmitted end-green from the arm interferes with the frequency-doubled PSL and produces a beatnote.
Line 22: Line 22:
 2. Changing the frequency of the end-green laser (using the PLL local oscillator) will affect it's resonance conditions in the arm cavity and excite the various transverse modes. 
 3. The frequencies at which these resonances occur depend on the spatial inhomogeneities on the mirror surface.
 2. Changing the frequency of the end-green laser (using the PLL local oscillator) will affect it's resonance conditions in the arm cavity and excite the various transverse modes.
 3. The frequencies at which the various transverse mode resonances occur depend on the spatial inhomogeneities on the mirror surface.

Tuning Fabry-Perot cavity modal frequencies using controlled thermoelastic deformations on mirror surface

Goal

To correct for the modal frequency shifts in the FP arm cavity that arise from the spatial inhomogeneities on the mirror surface. This will be done by imaging heat patterns on the ETM surface. The thermoelastic deformations created on the mirror surface introduces phase shifts to the cavity modes. The green ALS system will be used to mode scan the cavity continuously. A feedback control system will actively correct for the frequency shifts based on the cavity mode scan information.

The lessons learned from this exercise will help in designing/implementing a similar kind of system for the folding mirrors in the signal recycling cavity.

System Overview

CTD.pdf

Description

The PSL laser is locked to the arm cavity using the PDH error signal. The green laser is injected from the ETM side of the arm. The relative phase between the two lasers is kept constant using a phase-locked-loop (PLL) servo. The transmitted end-green from the arm interferes with the frequency-doubled PSL and produces a beatnote.

Taking into account the following:

  1. The amplitude of the beatnote depends on the intensity of the transmitted green.
  2. Changing the frequency of the end-green laser (using the PLL local oscillator) will affect it's resonance conditions in the arm cavity and excite the various transverse modes.
  3. The frequencies at which the various transverse mode resonances occur depend on the spatial inhomogeneities on the mirror surface.

We can conclude that the amplitude of the beatnote as a function of the end-laser frequency (or the local oscillator frequency) will give the information about the cavity resonance frequencies and hence the effect of the mirror distortions can be mapped.

Fact-finding

  1. What are the ideal cavity parameters? (a reference to compare the different heating models)
  2. Desired tuneable range and achievable range
  3. Heaters and heating patterns
  4. Practical/hardware limitations in implementing

Simulation/Modelling

  1. Find the ideal/real cavity parameters (higher order mode degeneracy) - SIS
  2. Frequency tuning - SIS
  3. Heating patterns - COMSOL
  4. Thermally perturbed cavity analysis - SIS